Permit Review Detail
Review Status: Completed
Review Details: PLANS OK TO SUBMIT - RES
Permit Number - T13CM06607
Review Name: PLANS OK TO SUBMIT - RES
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/01/2013 | DAVID RIVERA | ZONING | REVIEW | Denied | P&DS TRANSMITTAL FROM: David Rivera, Principal Planner PROJECT: T13CM06606 and T13CM06607 2602 E Copper Street Multi-family Development - 2 Dwelling Units Design Development Option required for building setbacks for both units TRANSMITTAL: November 1, 2013 COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1). This site is located in the R-2 zone (UDC 4.7.9). Multi-family residential is a permitted use in this zone (Table 4.8-2). ). See Use Specific Standards 4.9.7.B.6, .9 & .10. The minimum setback is the greater of ten (10) feet, or three-fourth (3/4) the height of the structure's wall facing each interior property line (Table 6.3-2.A). The minimum setback to a side street property line is ten (10) feet (UDC Section 6.4.5.C.1.b). Comment: MAIN DWELLING; 1. DDO is required for the Side Street yard (west side) building setback, required setback from street property line is ten (10) feet. The Owner proposes eight (8) feet from the side street property line. 2. DDO is required for the building setback along the East side yard. The required setback is based on the greatest of 10 feet or ¾ the height of the structure's wall adjacent to the East property line. The wall height of the patio is nine (9) feet. The minimum setback is ten (10) feet. The owner proposes seven (7) feet. Comment: SECOND DWELLING; 3. DDO is required for the rear yard (south) building setback, required setback from rear yard property line is the greatest of ten (10) feet or ¾ the height of the structure's wall adjacent to the South property line. The wall height of the second dwelling is 12'-4". The Owner proposes four (4) feet from the rear yard property line. 4. DDO is required for the building setback along the East side yard. The required setback is based on the greatest of 10 feet or ¾ the height of the structure's wall adjacent to the West property line. The wall height of the second dwelling is 12'-4". The required setback is nine (9) feet three (3) inches. The owner proposes six (6) feet. |
| 11/01/2013 | DAVID RIVERA | NPPO | REVIEW | Needs Review | |
| 11/01/2013 | DRIVERA1 | ENGINEERING | REVIEW | Needs Review | |
| 11/01/2013 | DRIVERA1 | BUILDING-RESIDENTIAL | REVIEW | Needs Review |