Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T13CM06514
Parcel: 10304001N

Review Status: Completed

Review Details: COMMERCIAL - TI

Permit Number - T13CM06514
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
10/25/2013 MARTIN BROWN FIRE REVIEW Approved
10/25/2013 LEERAY HANLY MECHANICAL-COMMERCIAL REVIEW Passed
10/25/2013 RAY MAJUTA ELECTRICAL-COMMERCIAL REVIEW Passed
10/25/2013 LHANLY1 WATER REVIEW Passed
10/25/2013 RONALD BROWN COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Passed
10/25/2013 LHANLY1 WWM REVIEW Passed
10/25/2013 LEERAY HANLY PLUMBING-COMMERCIAL REVIEW Passed
10/25/2013 JASON GREEN ENGINEERING REVIEW Approved October 25, 2013
FLOODPLAIN USE PERMIT NO.: T13OT01256
ADDRESS: 3495 W El Camino Del Cerro, Tucson Arizona 85745
PROPERTY OWNER: City Of Tucson
3495 W El Camino Del Cerro, Tucson Arizona 85745

The applicant is authorized to use a portion of the FEMA Special Flood Hazard Area Zone A floodplain per the Flood Insurance Rate Maps 04019C16669L, specifically described as:

A portion of Parcel 103-04-001N

For the purpose of constructing an open sided Ramada and revisions to Park Amenities.

The applicant agrees to comply with City of Tucson Floodplain and Erosion Hazard, and Watercourse Amenities, Safety and Habitat regulations, and is particularly bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Responsibility for renewal of this permit, if necessary, is with the applicant. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, Unified Development Code, or any other Federal, State, County, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under City of Tucson Floodplain and Erosion Hazard Regulations and Watercourse Amenities, Safety, and Habitat regulations require the issuance of an additional Floodplain Use Permit.

The following 8 conditions apply to this permit:
1) This permit becomes invalid and is subject to additional floodplain review, if any required development changes the construction of the open sided Ramada, or, if there is any further disturbance within the floodplain other than that outlined in this application. This floodplain use permit may be subject to conditions or restrictions designed to reduce or mitigate the potential damage or hazard to life or property resulting from the construction of a Ramada within the regulatory floodplain, floodway or erosion hazard areas as determined by the project engineer and accepted by the City of Tucson.
2) Except as approved by the City Engineer prior to the start of construction, development under this permit shall not obstruct, retard or divert the existing flow of floodwaters from or to adjacent properties.
3) All work shall conform to the approved Details and General site plan sheets for the construction of the Ramada, which are made part of this permit. The Ramada must remain open sided and can never be enclosed to a habitable structure.
4) Within 5 (five) days of issuance of this permit, and through completion of the project, notification must be posted and maintained in a conspicuous place on the job site stating "CONSTRUCTION PROCEEDING UNDER REQUIREMENTS OF CITY OF TUCSON FLOODPLAIN USE PERMIT # T13OT01256 FOR INFORMATION PLEASE CALL 791-5550."
5) This Floodplain Use Permit and plans shall be kept in a readily accessible location on site at all times.
6) Any additional future disturbance of the floodplain shall have separate floodplain use permit applications submitted to this office for review and approval.
7) See the associated activity T13CM06514
8) This permit is specific to the improvements for 3495 W EL Camino Del Cerro as indicated on the approved plans. It shall not apply to any other structure or property, whether attached or unattached, not specified under this permit.

Renewal of this permit will require a new application, review and approval of that application by the City of Tucson, Development Services Department, Engineering Division. This permit may be renewed for up to one year at the sole discretion of the City Engineer or designated representatives.

This Floodplain Use Permit will be automatically revoked and becomes invalid if conditions are not complied with, as set forth in this permit.

APPLICANT NAME: Stacy Weaks
ADDRESS: 418 N Toole Ave, Tucson Arizona 85701
PHONE: 520-622-9565
OWNER: COT Parks and Recs
ADDRESS: 900 S Randolph Way, Tucson Arizona 85716
PHONE: 520-791-4873

(EXPIRATION DATE) Month: 10 Day: 25 Year: 2014

SIGNATURE OF APPLICANT DATE

The applicant is authorized by the City Engineer to receive a floodplain use permit subject to the above referenced conditions and restrictions.
10/25/2013 DAVID RIVERA ZONING REVIEW Approved
10/25/2013 ANDREW CONNOR LANDSCAPE REVIEW Approved
10/25/2013 RONALD BROWN BUILDING-COMMERCIAL REVIEW Approved