Permit Review Detail
Review Status: Completed
Review Details: WALK THRU - RES
Permit Number - T13CM06488
Review Name: WALK THRU - RES
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/24/2013 | CLAYTON TREVILLYAN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | PLAN REVIEW COMMENTS Date: 10-24-13 Activity: T13CM06488 Address: 3701 N Park Av Applicant: Silverado Plumbing This letter reflects comments to be addressed. The purpose of this review is to verify compliance to the 2012 International Residential Code with local amendments. Other comment references may be derived from additional codes and standards adopted by The City of Tucson. All features have been checked only to the extent allowed by the submittals provided for review. All portions of this project are assumed to meet other departmental requirements, conditions, and concerns before permit approval. GENERAL REQUIREMENTS: 1. Specify size of electrical service, E3602.2. Note: Electrical services less than 150 amps must include an electrical load calculation to justify system capacity. 2. Specify roof framing and/or equipment supports capable of accommodating the proposed equipment load. 3. Provide Manual J/S/D calculations for the forced air unit in accordance with M1401.3, M1601.1. 4. The attached template has been provided for your convenience and can be found online at http://cms3.tucsonaz.gov/files/dsd/Permit-review/Air_Conditioning_Template.pdf If you have any questions please contact: Clayton Trevillyan 520.837.4913 Residential Plan Review |