Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - TI
Permit Number - T13CM06229
Review Name: COMMERCIAL - TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/10/2013 | JASON GREEN | ENGINEERING | REVIEW | Approved | |
| 10/11/2013 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Approved | |
| 10/11/2013 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Denied | 1. SHEET A100; CODE INFORMATION: REVISE THE CODE REFERENCES TO THE CURRENT EDITIONS USED BY THE CITY OF TUCSON. 2. SHEET A100; CODE INFORMATION: VERIFY THE CONSTRUCTION TYPE IS IV-B PER THE IBC CHAPTER 6. 3. SHEET A100: THE CITY OF TUCSON REQUIRES ALL LETTERING (UPPER AND LOWER CASE) TO BE A MINIMUM OF 3/32" IN HEIGHT. REVISE THE PROJECT DESCRIPTION AND CODE INFORMATION. 4. SHEET A100: THE SHEET INDEX INDICATES A00, A01, AND A02. THE ONLY SHEET IS A100. IN ADDITION, SHEET P02 IS NOT LISTED IN THE INDEX. REVISE. 5. GENERAL: PROVIDE A NOTE ON THE DRAWINGS THAT THE PLUMBING REQUIREMENTS OF THE IBC SECTION 29 ARE MET. 6. GENERAL: PROVIDE WRITTEN RESPONSES TO ALL REVIEW COMMENTS. |
| 10/11/2013 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | Clarify the installation of the reduced pressure backflow preventer for the dishwasher (i.e. show that it is accessible for maintenance). |
| 10/11/2013 | ROBERT SHERRY | WATER | REVIEW | Approved | |
| 10/11/2013 | RAY MAJUTA | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
| 10/11/2013 | STEVE SHIELDS | ZONING | REVIEW | Approved | |
| 10/11/2013 | ERIC NEWCOMB | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
| 10/14/2013 | KEN BROUILLETTE | FIRE | REVIEW | Denied | UPDATED CODES PLEASE |
| 10/16/2013 | AROMERO4 | WWM | REVIEW | Needs Review |