Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T13CM05984
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/09/2015 | CLAYTON TREVILLYAN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | PLAN REVIEW COMMENTS Date: 1-9-14 Activity: T14CM05984 Address: 6292 S. Beardslee Dr Applicant: Victor Flores This letter reflects comments to be addressed. The purpose of this review is to verify compliance to the 2012 International Residential Code with local amendments. In order to facilitate a shorter back check time, we request that you please provide two complete sets of revised plans and calculations, along with a written response to each of the noted items indicating action taken. Other comment references may be derived from additional codes and standards adopted by The City of Tucson. All features have been checked only to the extent allowed by the submittals provided for review. All portions of this project are assumed to meet other departmental requirements, conditions, and concerns before permit approval. Note: The plan set submitted for the second review is different than the original plan set. Additional comments may apply to this project as the current set of building plans has not been reviewed previously. PREVIOUS COMMENTS: These comments have not been addressed in the second submission and still apply. Correct the drawings accordingly. 1. Provide ΒΌ" = 1' scaled Floor Plan drawings with legible notation (minimum 3/32" lettering). This plan must show the proposed space and identification of adjacent existing rooms. 2. Show a header size with appropriate load carrying capacity, R301.1. The two 2 x 6 headers over 6' openings at the load bearing wall are undersized. 3. Specify water-resistive barrier equivalent to two layers of Grade D paper over the wood based sheathing of exterior plaster wall coverings, R703.6.3. 4. Provide heating facilities in all habitable rooms (New Family Room), R303.9. 5. Protect all new or extended 15A & 20A outlets (except bathrooms and kitchen) including receptacles, lights and smoke detectors with combination type arc-fault circuit interrupters, E3902.12. 6. Provide notation requiring tamper resistant receptacles for 125 volt, 15A and 20A receptacles, R4002.14. 7. Show the proposed fixtures as full cut-off FCO style, or provide an Outdoor Lighting Calculation including all exterior fixtures on the property for determining exterior lighting limits. Adjustable security light fixtures are unshielded, not FCO. NEW COMMENTS: 1. Doors between a garage and a residence shall be self-closing minimum 20-minute fire-rated, R302.5.1. 2. Specify the sizes of all roof support beams including porch hip, porch ends and window openings. 3. Provide section details for the proposed porch roof connection to the supporting beams with the proposed surrounding soffits. 4. Sill plates that rest on concrete are required to be decay-resistant, R317.1(2). 5. Provide exterior elevation drawings. 6. Specify the new location of the air conditioning units located where the proposed game room will be. 7. Designate the circuit number for each light fixture, receptacle, appliance, and equip disconnect on the electrical layout, E3703.5. 8. Provide a panel schedule: panel size, circuit numbers, ampacity, and wire sizes, E3404.11, E3706.2. 9. Provide a plumbing plan for the proposed powder room that includes drain, waste and vent layouts and water supply calculations for the entire property, P2903.7, P3005.2, P3101.1. 10. Provide a mechanical equipment specification list, M1302.1. 11. Provide Manual J/S calculations for the forced air unit in accordance with M1401.3, M1601.1. If you have any questions please contact: Clayton Trevillyan 520.837.4913 Clayton.Trevillyan@tucsonaz.gov Residential Plan Review |