Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

The login landing page when selecting 'View' is still occurring and is still pending further investigation. 

Permit Number: T13CM05561
Parcel: 126210250

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T13CM05561
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
10/09/2013 CLAYTON TREVILLYAN BUILDING-RESIDENTIAL REVIEW Reqs Change PLAN REVIEW COMMENTS
Date: 10-1-13
Activity: T13CM05561
Address: 3337 E. Via Golondrina
Applicant: ADG

This letter reflects comments to be addressed. The purpose of this review is to verify compliance to the 2012 International Residential Code with local amendments. In order to facilitate a shorter back check time, we request that you please provide two complete sets of revised plans and calculations, along with a written response to each of the noted items indicating action taken. Other comment references may be derived from additional codes and standards adopted by The City of Tucson. All features have been checked only to the extent allowed by the submittals provided for review. All portions of this project are assumed to meet other departmental requirements, conditions, and concerns before permit approval.

GENERAL REQUIREMENTS:
1. Specify detail for keynote #10 Sheet S2.1.
-Over framing referenced in keynote #10 is not shown on detail provided.

PLUMBING PLAN:
2. Provide a gas line isometric and size the supply pipe for the connected demand. Include the length of line and BTU demand for each appliance, size of each branch, total demand, and total developed length from meter to the most remote appliance on the system, G2413.1, Table G2413.4 (1).
-Provide a minimum 1½" gas line to laundry area branch line for proposed design.

MECHANICAL PLAN:
3. Correct references to Pima County sheet M1.1.
-Pima County code adoptions do not apply to projects located within the City limits.

ELECTRICAL PLAN:
4. Designate the circuit number for each light fixture, receptacle, appliance, and equip disconnect on the electrical layout, E3703.5.
-Furnace receptacle may not share the kitchen small appliance circuit.

OUTDOOR LIGHTING CODE
5. Provide cut sheets for all FCO fixtures showing the angle of cutoff, light emissions and fixture wattage. All other fixtures are assumed to be unshielded (non-FCO style)
-Cut sheets not found. Please note that flood style lighting devices are not considered fully shielded fixtures.

If you have any questions please contact:
Clayton Trevillyan
520.837.4913
Residential Plan Review

Final Status

Task End Date Reviewer's Name Type of Review Description
10/16/2013 FERNE RODRIGUEZ OUT TO CUSTOMER Completed
10/16/2013 CPIERCE1 REJECT SHELF Completed