| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/01/2013 | MARTIN BROWN | FIRE | REVIEW | Approved | Incorrect reference. I believe Mr. Brouillette was refering to the fact that a corridor with an occupant load served greater than 30 needs to be 1 hour rated with 20 minute doors. (Table 1018.1 in both 2012 IBC and IFC) |
| 10/02/2013 | RAY MAJUTA | ELECTRICAL-COMMERCIAL | REVIEW | Denied | T13CM05264 1395 W Miracle Mile Circle K Store 1. Last review dated 9/12/2013 indicated under item 2.E-- "Note all Outdoor Lighting even if on building must be minimum 3500K color rated temperature" as required per City of Tucson Outdoor Lighting Code 2012, Section 402.1. The following fixtures on sheet E1.2 show the following on the spec sheet, this could not be read last review due to the size of print submitted, CAN-304-PS-RS------------4300K STR-LWY-3M-HT----------4300K SEC-EDG-3M-WM---------4300K A60------------------not provided BO8-3M & 2BO8-3M-------3000K,35000K,4000K. Ray T Majuta Elect Plan Review PDSD, City of Tucson 10/2/2013 Ray.Majuta@tucsonaz.gov 520-837/4988 |
| 10/03/2013 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Approved | |
| 10/17/2013 | SPOWELL1 | PLUMBING-COMMERCIAL | REVIEW | Needs Review | |
| 10/17/2013 | SPOWELL1 | MECHANICAL-COMMERCIAL | REVIEW | Needs Review |