Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/WWM
Permit Number - T13CM05159
Review Name: RESIDENTIAL - BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/13/2013 | CLAYTON TREVILLYAN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | PLAN REVIEW COMMENTS Date: 11-14-13 Activity: T13CM05159 Address: 3757 E 25th St Applicant: Leonard Gonzales This letter reflects comments to be addressed. The purpose of this review is to verify compliance to the 2012 International Residential Code with local amendments. In order to facilitate a shorter back check time, we request that you please provide two complete sets of revised plans and calculations, along with a written response to each of the noted items indicating action taken. Other comment references may be derived from additional codes and standards adopted by The City of Tucson. All features have been checked only to the extent allowed by the submittals provided for review. All portions of this project are assumed to meet other departmental requirements, conditions, and concerns before permit approval. SITE PLAN: 1. Specify the location of all utility lines including feeder to detached storage building, R106.1.1. FLOOR PLAN: 2. Specify safety glazing in hazardous locations, R308.4 (Within 24" of doorways) 3. Clarify the location of the attic space to be ventilated per note #4 sheet 4. PLUMBING PLAN: 4. The Tucson Water policy adopted 7/13/12 limits the maximum demand for a 5/8" water meter to 15 GPM; indicate a ¾" water meter for the proposed water demand. Reference Tables P2903.6 and P2903.6 (1), IRC 2012. MECHANICAL PLAN: 5. Show exhaust fan locations for bathroom venting to the exterior (min 50 CFM rating), R303.3, M1507. ELECTRICAL PLAN: 6. Provide a complete panel schedule for the upgraded service panel, E3404.11, E3706.2. 7. Heating and cooling loads must be calculated at 100%, E3602.2. 8. Designate the 20-amp circuit to serve bathroom receptacles, E3703.4, E3901.6. 9. At least one wall switch controlled light must be provided at exterior door to carport area, E3903.3. 10. Correct reference to the 2006 IRC on note 8 sheet 7. 11. Provide carbon monoxide alarms per R315. Alarms must be installed in residences with attached garages and/or fuel-fired appliances when any work is performed that requires a permit. 12. All outlets specified in section E3902.12 shall be protected with combination-type arc-fault breakers (not just bedroom outlets). 13. Specify faceplate grounding per E4001.11.1. 14. Specify tamper resistant receptacles per E4002.14. OUTDOOR LIGHTING CODE 15. Show compliance with City of Tucson Outdoor Lighting Code with an approved lighting calculation in accordance with OLC 3.1.2. Include all exterior fixtures on the property in the calculations. Model plans should specify a minimum lot size for the proposed exterior lighting. INTERNATIONAL ENERGY CONSERVATION CODE: 16. Specify the "R" value of the insulation, as well as the "U" factor and the solar heat gain coefficient of the windows and doors. Tucson is in climate zone 2B. The simplified prescribed energy values for glazing and skylights is U=0.40, SHGC=0.25, ceiling R=38 and walls R=13. Mass wall requirement is R=4 when 50% of insulation is exterior and R=6 when applied interior, N1102.1. If you have any questions please contact: Clayton Trevillyan 520.837.4913 Residential Plan Review |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 12/04/2013 | CPIERCE1 | REJECT SHELF | Completed |