Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/WWM
Permit Number - T13CM05122
Review Name: RESIDENTIAL - BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/14/2014 | RAFAEL CANCINO | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | PLAN REVIEW COMMENTS Date: February 14,2014 Activity: T13CM05122 Address: 1378 E. Stewart Pl. Applicant: Mrs. Linda Lopez Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide revised plans and calculations, highlighting any changes or with a written response to each of the notated items indicating action taken. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2012 International Residential Code and 2012 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. GENERAL REQUIREMENTS: All engineers and architects involved in the design of the structure are to seal the related sheets of plans, details and calculations in accordance with the rules of the State Board of Technical Registration. The City of Tucson adopted the 2012 IRC with amendments on 1/1/2012. Show the code references on the plans. GENERAL NOTES: " Limit all code references to those recognized by the City of Tucson. Adopted 2012 codes are listed at the Planning & Development Services web site. Show the code references used for the design. FOUNDATION PLAN (SHEET 2): 1. Change "Floor Plan" label to "Foundation Plan". 2. Change footer depth to 12" below undisturbed soil on all details. FLOOR PLAN: 1. Existing structural members are not adequate for required insulation requirements. If all room designations are changed to storage, then insulation is not required. 2. Install exterior rated door between existing dining room and new family room to create storage room. FRAMING PLAN: 1. Existing carport rafters are 2X6, if you attach 18 gage C-channel on each side and fasten at 12" o/c (staggered) there may not be a need to replace existing rafters, please verify. 2. Existing room rafters may be reinforced with 18 gage C-channels of same size, anchored at 12" o/c and may not need replacement. Please verify. DETAIL PLAN: 1. Change foundation to reflect 12" below undisturbed soil per IRC requirements. If you have any questions please contact: Rafael Cancino (520) 909-4891 City of Tucson Residential Plan Review |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 02/20/2014 | FERNE RODRIGUEZ | OUT TO CUSTOMER | Completed |