Permit Number: T13CM05014
Parcel: 12801005H

Review Status: Completed

Review Details: COMMERCIAL - TI

Permit Number - T13CM05014
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/15/2013 MARTIN BROWN FIRE REVIEW Approved
08/15/2013 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Passed
08/15/2013 RAY MAJUTA ELECTRICAL-COMMERCIAL REVIEW Approved
08/15/2013 ROBERT SHERRY WATER REVIEW Approved
08/15/2013 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Approved
08/15/2013 LOREN MAKUS ENGINEERING REVIEW Approved
08/15/2013 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Denied 1. The new 3" horizontal drain is shown connecting to an existing 4" building drain. Does the 4" building drain have an existing cleanout located upstream of the new connection or is the connection at the upstream terminal of the 4" building drain.
2. Indirect waste piping that has a developed length greater than 30-inches (30") when measured horizontally or greater than 54-inches (54") in total developed length shall be trapped. Exception: indirect waste piping conveying only clear-water waste (e.g. effluent from a sanitizing compartment) does not require a trap. Reference: Section 802.2, IPC 2012.
08/15/2013 ERIC NEWCOMB COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Passed
08/16/2013 STEVE SHIELDS ZONING REVIEW Approved
08/21/2013 GERRY KOZIOL WWM REVIEW Approved