Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T13CM04762
Parcel: 135021930

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/WWM

Permit Number - T13CM04762
Review Name: RESIDENTIAL - BLDG/WWM
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/26/2013 KEN VAN KARSEN BUILDING-RESIDENTIAL REVIEW Denied T13CM04762
PLAN REVIEW COMMENTS

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, highlighting any changes, along with a written response to each of the notated items indicating action taken.

SCOPE OF REVIEW:

The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2012 International Residential Code and 2012 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.

FOUNDATION PLANS:

1. Framed exterior walls of enclosed roof structures require continuous concrete footings of minimum 12" width and 12" below undisturbed ground surface, R403.1. Show a continuous footing at the enclosed Carport exterior walls similar to Detail #1/4.

STRUCTURAL PLANS:

1. Clarify the 2" x 16" roof joist size shown on the Roof Plan, R301.1. Section A-A shows 2" x 6" roof joist.
2. Clarify Section B-B for consistency with the Roof Plan which shows 2" x 10" roof joist, R301.1.

SECTIONS - DETAILS:

1. Show a post/beam fastener with appropriate uplift capacity at Detail #2/4, R802.11.
2. Clarify General Framing Note #4/3. Eave ventilation is not appropriate without attic space, or rafter cavity space between insulation and roof sheathing, R806.1.

PLUMBING PLANS:

1. Notate "no underground gas piping exists beneath building", G2415.11.

MECHANICAL PLANS:

1. Provide heating facilities in all habitable rooms (Sitting Room), R303.8.

ELECTRICAL PLANS:

1. Clarify the Service size, R301.1. Sheet #1 & 5 shows 200A although the existing building Load Calculation and Panel Schedule shows 100A, which is consistent with permit #T98EL01159.
2. Smoke alarms are required outside each separate sleeping area, R313.2. Show a smoke alarm on each side of the bedroom doors.
3. Show or notate the requirement for a carbon monoxide detector outside of bedroom doors, when the dwelling includes an attached garage or gas appliance, R315.
4. Provide a single panel schedule showing panel showing actual circuit numbers, E3404.11 & E3706.2.
5. Protect all 15A & 20A outlets (except bathrooms and kitchen) including receptacles, lights and smoke detectors with combination type arc-fault circuit interrupters, E3902.12. Update note #11.

INTERNATIONAL ENERGY CONSERVATION CODE:

1. Tucson is in climate zone 2B. The simplified prescribed energy values for glazing is U=0.40, skylights U=0.65, ceiling R=38 and walls R=13. Show the maximum "U" factors of the windows, N1102.1.

If you have any questions please contact:
Ken Van Karsen
(520) 837-4912
City of Tucson Residential Plan Review

Final Status

Task End Date Reviewer's Name Type of Review Description
08/30/2013 CPIERCE1 REJECT SHELF Completed