Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T13CM04719
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/21/2013 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Denied | Provide sufficient detail on the drawings to evaluate the energy compliance of the building envelope. The exterior wall descriptions (sheet 1.1.1) call for continuous R-5 insulation but no cavity insulation; the COMcheck component description shows R-4 continuous insulation and R-18 cavity insulation. The window notes (sheet 8.1) do not include the U-factor or the solar heat gain coefficient for the windows. [Initial comment: Provide energy code compliance calculations for the building envelope, the mechanical systems, and the interior lighting; use the climate zone for Tucson. Provide sufficient detail on the drawings to evaluate the energy compliance of the building envelope. The information shall, as a minimum, include U-factors of the envelope systems and fenestration components, along with the R-values of the insulation and the SHGC for the fenestration. Reference: Sections C103.2 and C401.2, International Energy Conservation Code 2012.] |
| 10/21/2013 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | 1. Provide the registrant's seal on sheet P1.6. [Initial comment: Provide plans sealed by an Arizona Registrant. Reference: Arizona Revised Statutes 32-125, Board of Technical Registration Rules R4-30-304.] 2. Revise the size of the natural gas pipe located between the branch serving DOA-1 and the branch serving AC-1 in detail 3/P1.4. [Initial comment: Revise the size of the natural gas pipe located between the branch serving DOA-1 and the branch serving AC-1. Reference: Section 402.4, IFGC 2012.] |
| 10/22/2013 | RAY MAJUTA | ELECTRICAL-COMMERCIAL | REVIEW | Denied | T13CM04719 2221 N Rosemont Last review sheet dated 8/26/2013, requested 2012 IECC Lighting Compliance Report. Letter from Enrique Giron indicates one has been provided, could not find one submitted with plans ? Ray T Majuta Electrical Plan Review PDSD, Tucson 10/22/2013 520/837/4988 Ray.Majuta@tucsonaz.gov |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 10/24/2013 | CPIERCE1 | REJECT SHELF | Completed |