Review Details: PLANS OK TO SUBMIT - RES
Permit Number - T13CM04214
Review Name: PLANS OK TO SUBMIT - RES
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/11/2013 | MICHAEL ST. PAUL | ZONING | REVIEW | Denied | P&DS TRANSMITTAL FROM: Michael St.Paul, Planning Technician PROJECT: T13CM04214 1721 E Holladay Addition with carport to SFR TRANSMITTAL: July 11, 2013 COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1). This site is located in the R-1 zone (UDC 4.7.8). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9. The minimum setback to the front street perimeter property line is the greater of twenty (20) feet, or one and one-half (1 ½) the height of the proposed wall ((UDC 6.4.5.C.1.a). The required front setback is twenty (20) feet. The proposed setback is eight (8) feet. The DDO process may only be used to reduce the driveway length to a carport, and not to a garage (UDC Section 6.4.5.C.2.b.1.c). The minimum driveway length to the edge of a sidewalk for a carport is nineteen (19) feet (UDC Section 6.4.5.C.2.b.1). The minimum driveway length for a carport is eighteen feet to the property line (UDC Section 6.4.5.C.2.b.1.a & b). The proposed driveway length from the carport to the property line is eight (8) feet. |
| 10/21/2013 | AROMERO4 | WWM | REVIEW | Needs Review | |
| 10/21/2013 | AROMERO4 | NPPO | REVIEW | Needs Review | |
| 10/21/2013 | AROMERO4 | ENGINEERING | REVIEW | Needs Review | |
| 10/21/2013 | AROMERO4 | BUILDING-RESIDENTIAL | REVIEW | Needs Review |