Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/WWM
Permit Number - T13CM03940
Review Name: RESIDENTIAL - BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/12/2013 | CLAYTON TREVILLYAN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | PLAN REVIEW COMMENTS Date: 8-12-13 Activity: T13CM03940 Address: 718 W44th St Applicant: Dana Holguin This letter reflects comments to be addressed. The purpose of this review is to verify compliance to the 2012 International Residential Code with local amendments. In order to facilitate a shorter back check time, we request that you please provide two complete sets of revised plans and calculations, along with a written response to each of the noted items indicating action taken. Other comment references may be derived from additional codes and standards adopted by The City of Tucson. All features have been checked only to the extent allowed by the submittals provided for review. All portions of this project are assumed to meet other departmental requirements, conditions, and concerns before permit approval. GENERAL REQUIREMENTS: 1. The City of Tucson has adopted the 2012 International family of codes. As of 1/01/2013 all code references should refer to the currently adopted code or appeal must be made to the Building Official for use of the Uniform Building code specified on sheet T1.1. 2. Show compliance with City of Tucson Outdoor Lighting Code with an approved lighting calculation in accordance with OLC 3.1.2. Include all exterior fixtures on the property in the calculations. Model plans should specify a minimum lot size for the proposed exterior lighting. SITE PLAN: 3. Specify the location of all utility lines and service meters, R106.1.1. FLOOR PLAN: 4. Specify the size and operation of each proposed window, R310. FOUNDATION PLAN: 5. Provide the minimum sized footings under proposed masonry walls near the proposed hallway and bedroom #4. STRUCTURAL / FRAMING PLAN: 6. Specify lumber grade/species, R802.1. Minimum douglas fir #1 or better will be required for the proposed span of the porch beams. 7. Clarify the proposed ledger attachment to the masonry wall on detail 8-A2.1 (nails?) 8. Clarify references to structural members 'B2' and 'L2' on framing plan. PLUMBING PLAN: 9. Provide a gas supply piping diagram with the lengths of branch lines, diameter of proposed piping and an equipment schedule with input demands. ELECTRICAL PLAN: 10. Specify faceplate grounding per E4001.11.1. 11. Specify tamper resistant receptacles per E4002.14. 12. Show the location of the electric service panel on the electrical layout. INTERNATIONAL ENERGY CONSERVATION CODE: 13. Specify the "U" factor and the solar heat gain coefficient of the windows and doors. Tucson is in climate zone 2B. The simplified prescribed energy values for glazing and skylights is U=0.40, SHGC=0.25, N1102.1. If you have any questions please contact: Clayton Trevillyan 520.837.4913 Residential Plan Review |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 08/13/2013 | CPIERCE1 | REJECT SHELF | Completed |