Permit Review Detail
Review Status: Active
Review Details: RESUBMITTAL
Permit Number - T13CM03566
Review Name: RESUBMITTAL
Review Status: Active
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/07/2013 | CLAYTON TREVILLYAN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | PLAN REVIEW COMMENTS Date: 8-7-13 Activity: T13CM03566 2nd review Address: 8916 E Harborage Dr Applicant: Richard Phelps This letter reflects comments to be addressed. The purpose of this review is to verify compliance to the 2012 International Residential Code with local amendments. In order to facilitate a shorter back check time, we request that you please provide two complete sets of revised plans and calculations, along with a written response to each of the noted items indicating action taken. Other comment references may be derived from additional codes and standards adopted by The City of Tucson. All features have been checked only to the extent allowed by the submittals provided for review. All portions of this project are assumed to meet other departmental requirements, conditions, and concerns before permit approval. STRUCTURAL / FRAMING PLAN: 1. Specify roof framing support over proposed openings in existing walls, R801.2. Existing lintel over sliding glass door to be removed will be supporting additional roof structure. Justify structural capacity of member or provide alternate support for proposed new roof framing. ELECTRICAL PLAN: 2. Laundry rooms require at least one 20-amp circuit that shall serve no other outlets, E3703.3, 3901.8. 3. Bathrooms require a separate 20-amp circuit with receptacles within 3' of the basin, E3703.4, E3901.6. Both of these circuits include lighting which is prohibited to share the require receptacles that serve these spaces. If you have any questions please contact: Clayton Trevillyan 520.837.4913 Residential Plan Review |