Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/WWM
Permit Number - T13CM03566
Review Name: RESIDENTIAL - BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/11/2013 | CLAYTON TREVILLYAN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | PLAN REVIEW COMMENTS Date: 7-12-13 Activity: T13CM03566 Address: 8916 E Harborage Dr Applicant: Richard Phelps This letter reflects comments to be addressed. The purpose of this review is to verify compliance to the 2012 International Residential Code with local amendments. In order to facilitate a shorter back check time, we request that you please provide two complete sets of revised plans and calculations, along with a written response to each of the noted items indicating action taken. Other comment references may be derived from additional codes and standards adopted by The City of Tucson. All features have been checked only to the extent allowed by the submittals provided for review. All portions of this project are assumed to meet other departmental requirements, conditions, and concerns before permit approval. FLOOR PLAN: 1. Specify size of openings in existing walls between bedroom/sunroom and bathroom/closet. FOUNDATION PLAN: 2. Specify the width and depth of proposed footings, R403. STRUCTURAL / FRAMING PLAN: 3. Specify roof framing support over proposed openings in existing walls, R801.2. 4. Indicate roof framing support under rafters in porch area on east side of building, R801.2. MECHANICAL PLAN: 5. Show exhaust fan locations for bathroom venting to the exterior (min 50 100 CFM rating), R303.3, M1507. PLUMBING PLAN: 6. Storage of gray water must meet Arizona Department of Environmental Quality BMPs. Indicate compliance for harvesting tank and provide cross section detail of piping and tank layout. ELECTRICAL PLAN: 7. Provide a panel schedule: panel size, circuit numbers, ampacity, and wire sizes, E3404.11, E3706.2. 8. Designate the circuit number for each light fixture, receptacle, appliance, and equip disconnect on the electrical layout, E3703.5. 9. Laundry rooms require at least one 20-amp circuit that shall serve no other outlets, E3703.3, 3901.8. 10. Bathrooms require a separate 20-amp circuit with receptacles within 3' of the basin, E3703.4, E3901.6. 11. All outlets specified in section E3902.12 shall be protected with combination-type arc-fault breakers (not just bedroom outlets). OUTDOOR LIGHTING CODE 12. Show compliance with City of Tucson Outdoor Lighting Code with an approved lighting calculation in accordance with OLC 3.1.2. Include all exterior fixtures on the property in the calculations. Model plans should specify a minimum lot size for the proposed exterior lighting. If you have any questions please contact: Clayton Trevillyan 520.837.4913 Residential Plan Review |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 07/16/2013 | GERARDO BONILLA | REJECT SHELF | Completed |