Permit Number: T13CM03217
Parcel: 129134460

Address:
732 E 35TH ST

Review Status: Completed

Review Details: PLANS OK TO SUBMIT - RES

Permit Number - T13CM03217
Review Name: PLANS OK TO SUBMIT - RES
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/28/2013 MICHAEL ST. PAUL ZONING REVIEW Approved
05/28/2013 MICHAEL ST. PAUL NPPO REVIEW Passed
05/30/2013 LOREN MAKUS ENGINEERING REVIEW Approved May 30, 2013, (Elevation Certificate Required)

The applicant is authorized to use a portion of the flood hazard area (FEMA Zone X, Panel 2279L, COT Flood Hazard Area) in the City of Tucson at 732 East 35th Street for the purpose of constructing a new residential structure.

The applicant agrees to comply with City of Tucson Floodplain and Erosion Hazard regulations, and is particularly bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Responsibility for renewal of this permit, if necessary, is with the applicant. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, Land Use Code, or any other Federal, State, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under City of Tucson Floodplain and Erosion Hazard Regulations and Watercourse Amenities, Safety, and Habitat regulations require the issuance of an additional Floodplain Use Permit.

The following conditions shall apply to this permit.

1. All work shall conform to the attached plans (T13CM03217) which are made part of this permit.

2. The lowest floor of the residence and all equipment serving the structure must be placed at least one foot above the base flood elevation.

3. The floodplain 100-year water surface elevation (WSE) just upstream of the pad is 2449.66 feet. The lowest floor including the garage floor, utilities, machinery, equipment (i.e. furnaces, water heaters, heat pumps, air conditioners and their associated equipment, including all electrical equipment), or an open utility platform that provides utility services for the structure on this property, under this permit shall, be placed at a minimum of 2450.66 feet above sea level, NAVD88 as certified by a Registered Land Surveyor. This Certification (Elevation Certificate) is required and must be completed and returned to Development Services Department, Engineering Division, on the first floor of the County/City Public Works Building at 201 North Stone Avenue. This Certification must be completed and returned prior to the final inspection, occupancy of the structure, or issuance of Certificate of Occupancy. A preliminary elevation certificate is required before the floor slab is poured.

4. The existing drainage patterns at the property lines shall not be obstructed.

5. Except as approved by the City Engineer prior to the start of construction, development under this permit shall not obstruct, retard or divert the existing flow of floodwaters from or to adjacent properties.

6. This permit becomes invalid and is subject to additional floodplain review, if any required development permit (s') changes the configuration of the structure and or site development.

7. The completed elevation certificate and anchoring certificate must be submitted to the City of Tucson, Planning and Development Services Department, Engineering Counter, 201 North Stone Avenue prior the issuance of a Certificate of Occupancy.

8. New chain link fence on the property line is included in this permit. Any patio walls now or in the future to be constructed will require a separate Floodplain Use Permit.

This Floodplain Use Permit will be automatically revoked and becomes invalid if conditions set forth in this permit are not complied with.
05/30/2013 CLAYTON TREVILLYAN BUILDING-RESIDENTIAL REVIEW Needs Review
05/31/2013 GERRY KOZIOL WWM REVIEW Approved