Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - TI
Permit Number - T13CM02860
Review Name: COMMERCIAL - TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/13/2013 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Denied | 1. SHEET G100; APPLICABLE CODES: THE ACCESSIBILITY CODE FOR THE CITY OF TUCSON IS THE ICC/ANSI A117.1-2009. REVISE ON THE DRAWING. 2. SHEET G100: PROVIDE A CODE ANALYSIS ON THIS SHEET, INCLUDING THE OCCUPANCY GROUP, CONSTRUCTION TYPE, AND OCCUPANCY SQUARE FOOTAGE. 3. SHEET G101; DETAIL 35/G102: PROVIDE A VERTICAL GRAB BAR AT THE WATER CLOSET PER THE ICC/ANSI A117.1-2009, FIGURE 604.5.1. 4. SHEET G101: THE CITY OF TUCSON REQUIRES ALL LETTERING (UPPER AND LOWER CASE) TO BE A MINIMUM OF 3/32" IN HEIGHT. REVISE THE DETAILS AND TITLES. 5. SHEET A300; RESTROOM ELEVATIONS: INDICATE THE VERTICAL GRAB BAR ON THE ELEVATIONS. 6. GENERAL: PROVIDE WRITTEN RESPONSES TO ALL REVIEW COMMENTS. SUBSEQUENT REVIEWS WILL NOT BE PERFORMED WITHOUT RESPONSES. |
| 05/13/2013 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Passed | |
| 05/13/2013 | RAY MAJUTA | ELECTRICAL-COMMERCIAL | REVIEW | Denied | T13CM02860 Provide an updated panel schedule showing current loads, show location of panel, assign circuit numbers to lighting circuits along with panel designations. Ray Majuta El Plan Ck 5/13/13 |
| 05/13/2013 | ROBERT SHERRY | WATER | REVIEW | Denied | Provide the sizes of the water meter and the backflow preventer serving this building. |
| 05/13/2013 | ERIC NEWCOMB | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Passed | |
| 05/13/2013 | LAITH ALSHAMI | ENGINEERING | REVIEW | Approved | |
| 05/13/2013 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | Clarify the extent of the plumbing work |
| 05/14/2013 | KEN BROUILLETTE | FIRE | REVIEW | Denied | 1. SHEET G100: PROVIDE A CODE ANALYSIS ON THIS SHEET, INCLUDING THE OCCUPANCY GROUP, CONSTRUCTION TYPE, OCCUPANCY SQUARE FOOTAGE, AND TOTAL OCCUPANT LOAD. 2. INDICATE ON PLANS WHETHER OR NOT A FIRE SPRINKLER AND/OR FIRE ALARM SYSTEM EXISTS, AND IF ALTERATIONS TO THESE SYSTEMS ARE PLANNED UNDER SEPARATE SUBMITTAL. |
| 06/24/2013 | CPIERCE1 | WWM | REVIEW | Needs Review | |
| 06/24/2013 | CPIERCE1 | ZONING | REVIEW | Needs Review |