Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/WWM
Permit Number - T13CM02690
Review Name: RESIDENTIAL - BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/21/2013 | RAFAEL CANCINO | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | PLAN REVIEW COMMENTS Date: October 22,2013 Activity: T13CM02690 Address: 31 E. Delta Rd Applicant: Mr. Frank Rendon Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, please provide revised plans and calculations, highlighting any changes or with a written response to each of the notated items indicating action taken. SCOPE OF REVIEW: The scope of this plan review covers architectural, plumbing, mechanical, energy conservation and electrical. All code references are to the 2012 International Residential Code and 2012 International Energy Conservation Code. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. GENERAL REQUIREMENTS: All engineers and architects involved in the design of the structure are to seal the related sheets of plans, details and calculations in accordance with the rules of the State Board of Technical Registration. The City of Tucson adopted the 2012 IRC with amendments on 1/1/2012. Show the code references on the plans. GENERAL NOTES: " Limit all code references to those recognized by the City of Tucson. Adopted 2012 codes are listed at the Planning & Development Services web site. Show the code references used for the design. " Any portion of building, including overhangs, that are closer than three feet to property line must be built to one-hour fire rating. FOUNDATION PLANS: 1. Reference structural details to foundation plan. FLOOR PLAN: 1. Reference applicable sections and details to floor plan location. DETAIL PLAN: 1. Identify details on sections. 2. Detail #3 at sheet A3 requires more detail, including method of connections to slab and to existing residence. FRAMING PLAN: 1. Justify 2X8 rafters at bedroom. 2. Identify and justify center beam in garage. 3. Justify 2X6 rafters in garage. 4. Provide header schedule. ELECTRICAL PLANS: 1. Identify power source and circuit for mechanical equipment. 2. Identify main power panel location. 3. Provide main power panel schedule. 4. Identify light switches in garage as three-way. If you have any questions please contact: Rafael Cancino (520) 909-4891 City of Tucson Residential Plan Review |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 10/23/2013 | CPIERCE1 | REJECT SHELF | Completed |