Permit Number: T13CM02690
Parcel: 138100300

Address:
31 E DELTA RD

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/ZONING-WALKTHRU

Permit Number - T13CM02690
Review Name: RESIDENTIAL - BLDG/ZONING-WALKTHRU
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/18/2013 DAVID RIVERA ZONING REVIEW Denied ROM: David Rivera
Principal Planner

PROJECT: Activity No: T13CM02690
Site Address: #! E Delta Road
Project: Bedroom and Two-car Garage

TRANSMITTAL DATE: June 18, 2013


COMMENTS:

Prior to approval of the plot and building plans a Design Development Option approval for the Garage building setback is required to allow the proposed garage building setbacks of three (3) feet along the West property line.

1. LUC section 2.2.6.4 perimeter yard matrix designator (AA) R-2 zoning, Adjacent to R-2 Zoning, minimum building setback is the greater of (6 feet or 2/3rds) 9'-8" the height of the exterior wall.

A DDO is required for to allow the three-foot building setback along the West property line. The exterior building wall height is proposed at 9'-8". The required building setback is based on the greatest of (six feet or 2/3rds) the height of the exterior wall. The minimum building setback required is 6'-6".

Both structures on this permit have been built by the owner without permits. The owner has been issued a notice of violation (T12DV08720) and these plans have been submitted for review to ensure compliance with current code requirements. The owner has chosen to exercise the right to use the LUC code requirements and any previous determination related to accessory structures. The detached accessory structure is less than 50% the overall square footage of the principal structure 1669 square feet. The adjacent owners of the property could not be contacted and were sent a registered letter for there concurrence on the detached accessory setback waiver but got no response. Due to no signature from the adjacent owners to waiving the building setback for the garage structure the owner is required to submit DDO application for review and approval.

If you have any questions about this transmittal, please call David Rivera, (520) 837-4957.
06/18/2013 DRIVERA1 ENGINEERING REVIEW Needs Review
06/18/2013 DAVID RIVERA NPPO REVIEW Passed
06/18/2013 DRIVERA1 BUILDING-RESIDENTIAL REVIEW Needs Review