Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - TI
Permit Number - T13CM02682
Review Name: COMMERCIAL - TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/03/2013 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Denied | 1. SHEET TS.1; SHEET INDEX: SHEETS S.1 AND S.2 ARE LISTED ON THE INDEX, BUT NOT INCLUDED IN THE SET. PROVIDE. 2. SHEET TS.1; PROJECT DATA: UNDER THE OCCUPANCY, AN ENCLOSED PATIO IS INCLUDED IN THIS PROJECT. WHERE ARE THE PATIO AND DETAILS SHOWN, OR IS IT EXISTING? VERIFY. 3. SHEET A.1; FLOOR PLAN: INDICATE A NORTH ARROW ON THE PLAN. 4. SHEET A.1; FLOOR PLAN: THE COLUMN AT THE MAIN ENTRY TRELLIS CAN NOT BE IN THE SLOPE OF THE HANDICAP RAMP. REVISE. 5. GENERAL: PROVIDE WRITTEN RESPONSES TO ALL REVIEW COMMENTS. |
| 05/03/2013 | ERIC NEWCOMB | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Approved | |
| 05/06/2013 | RAY MAJUTA | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
| 05/06/2013 | KEN BROUILLETTE | FIRE | REVIEW | Approved | |
| 05/13/2013 | LOREN MAKUS | ENGINEERING | REVIEW | Approved | |
| 05/17/2013 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | 1. Show how the exposed water pipes are to be protected from freezing. Reference: Section 305.4, IPC 2012 2. The developed length of the revised hot water supply piping appears to be greater than fifty feet; provide a method for maintaining the temperature of the hot water supply system. Reference: Section 607.2, IPC 2012. 3. Show how combustion and dilution air is being provided for the water heater and the dryer. Reference: Section 304, IFGC 2012. |
| 05/17/2013 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Passed | |
| 05/17/2013 | ROBERT SHERRY | WATER | REVIEW | Approved | |
| 05/29/2013 | CPIERCE1 | ZONING | REVIEW | Needs Review | |
| 05/29/2013 | CPIERCE1 | WWM | REVIEW | Needs Review |