Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T13CM02629
Parcel: 140290480

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T13CM02629
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/04/2013 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Approved
06/04/2013 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Denied 1. See referenced code sections for resolving this comment. [Initial comment: Show how the temperature of the hot water supply to the public lavatories is controlled. Reference: Sections 416.5, 607.1 and 607.1.2, IPC 2012 and Section C404.3, IECC 2012.]
2. The material specifications allow the use of ABS in the plenum, a combustible material. [Initial comment: Materials exposed in plenums shall conform to Section 602.2.1, IMC 2012.]
06/04/2013 RAY MAJUTA ELECTRICAL-COMMERCIAL REVIEW Approved