Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - TI
Permit Number - T13CM02392
Review Name: COMMERCIAL - TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/24/2013 | MARTIN BROWN | FIRE | REVIEW | Approved | |
| 05/03/2013 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Denied | 1. SHEET G0.1; PROJECT CODES: THE IBC, IEBC, IMG, IECC, IFGC, IPC, AND IFC ARE ALL CURRENTLY USING THE 2012 EDITION, WHILE THE NEC IS USING THE 2011 EDITION. ADD THE ICC/ANSI A 117.1-2009 ACCESSIBILITY CODE. 2. SHEET A1.1; WALL LEGEND: PROVIDE THE NEW 4" WALL METAL STUD GAUGE AND SPACING. 3. SHEET A1.1; WALL LEGEND: PROVIDE THE NEW 5" WALL METAL STUD GAUGE AND SPACING. IS 5" CORRECT? VERIFY. 4. SHEET A1.2; DEMOLITION PLAN LEGEND: THIS IS NOT A DEMOLITION PLAN. REVISE THE TITLE. 5. SHEET A4.1; DETAIL 11: A NOTE INDICATES STEEL STUDS PER SCHEDULE. WHERE IS THE SCHEDULE? PROVIDE. 6. SHEET A4.2; MOUNTING HEIGHT SCHEDULE: ADD THE TOILET PAPER DISPENSER LOCATION PER THE ICC/ANSI FIGURE 604.9.2. 7. GENERAL: PROVIDE WRITTEN RESPONSES TO ALL REVIEW COMMENTS. NO SUBSEQUENT REVIEWS WILL BE PERFORMED WITHOUT RESPONSES. |
| 05/10/2013 | RAY MAJUTA | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
| 05/13/2013 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | 1. Revise all of the drains for the two 3-compartment sinks, PL3C-18 and PL3C-20, (detail PSD-7/P5.2) to be independently routed to an indirect waste receptor and terminated with an air gap. Reference: Sections 801.2 and 802.1, IPC 2012. 2. Plumbing schematic B/P6.1 shows two new horizontal vents below the floor; this is not allowed under the 2012 IPC. Reference: Section 905.4, IPC 2012. |
| 05/13/2013 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Passed |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 05/22/2013 | CPIERCE1 | REJECT SHELF | Completed |