Permit Number: T13CM02273
Parcel: 12415017A

Address:
960 E 17TH ST

Review Status: Completed

Review Details: COMMERCIAL - TI

Permit Number - T13CM02273
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/17/2013 MARTIN BROWN FIRE REVIEW Approved
04/17/2013 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Approved
04/17/2013 RAY MAJUTA ELECTRICAL-COMMERCIAL REVIEW Approved
04/17/2013 ROBERT SHERRY WATER REVIEW Approved
04/17/2013 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Denied 1. SHEET A1; FLOOR PLAN: IT IS NOT CLEAR WHAT THE AREA FOR THIS TENANT IMPROVEMENT IS, AND WHAT THE OCCUPANT LOAD FOR THAT AREA IS. PLEASE CLARIFY ON SHEET A1.
2. SHEET A1; FLOOR PLAN: EXIT FROM THE NEW TENANT IMPROVEMENT AREA MUST PASS THROUGH THE SHIPPING AND RECEIVING AREA OF THE CURRENT BUILDING. PROVIDE A DEMARCATION ON THE FLOOR INDICATING AN EXIT PATH FROM THE TENANT IMPROVEMENT AREA TO AN EXIT. REFERENCE 2012 IBC SECTION 1024.
3. GENERAL: PER IBC SECTION 3411.7, PROVIDE AN ESTIMATE OF THE COST PERTAINING TO ACCESSIBILITY (UP TO A MAXIMUM OF 20% OF PROJECT COST).
4. GENERAL: PROVIDE WRITTEN RESPONSES FOR ALL REVIEW COMMENTS.
04/17/2013 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Denied Revise the drains from the 3-compartment sink to provide independent indirect wastes from all of the compartments. Reference: Sections801.2 and 802.1.8, IPC 2012.
04/17/2013 ERIC NEWCOMB COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Passed
04/18/2013 FRODRIG2 WWM REVIEW Passed
04/18/2013 FRODRIG2 ZONING REVIEW Needs Review
04/18/2013 LOREN MAKUS ENGINEERING REVIEW Approved