Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T13CM02221
Parcel: 13320004A

Review Status: Completed

Review Details: RESIDENTIAL - BLDG/WWM

Permit Number - T13CM02221
Review Name: RESIDENTIAL - BLDG/WWM
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/07/2013 CLAYTON TREVILLYAN BUILDING-RESIDENTIAL REVIEW Reqs Change PLAN REVIEW COMMENTS
Date: 5-10-13
Activity: T13CM02221
Address: 804 N Shepherd Hills
Applicant: Letitia Grave

This letter reflects comments to be addressed. The purpose of this review is to verify compliance to the 2012 International Residential Code with local amendments. In order to facilitate a shorter back check time, we request that you please provide two complete sets of revised plans and calculations, along with a written response to each of the noted items indicating action taken. Other comment references may be derived from additional codes and standards adopted by The City of Tucson. All features have been checked only to the extent allowed by the submittals provided for review. All portions of this project are assumed to meet other departmental requirements, conditions, and concerns before permit approval.

GENERAL REQUIREMENTS:
1. Correct reference to the 2012 NEC. The currently adopted National Electric Code is the 2011 edition.
2. Provide accurate code references on sheet 9

INCLUSIVE HOME DESIGN:
3. Provide a complete set of notes on the plan to meet the Inclusive Home Design Ordinance 10463.

FLOOR PLAN:
4. Specify safety glazing in hazardous locations, R308.4. Less than 60" above and within 60" horizontally from tub/shower floors and within 24" of doorways.

PLUMBING PLAN:
5. All construction drawings submitted after June 1, 2010 for one- or two-family dwellings must provide segregated building drains for future gray water utilization, P2601.2.1.
6. Details are required for island venting (air admittance valves/Chicago Loops), P3112.
7. Specify the proposed water meter size on the site plan (minimum ¾" meter required for proposed demand).
8. Provide note requiring that water hammer arrestor be installed in accordance with ASSE 1010-2004 on water lines serving appliances equipped with quick-closing valves to include but not limited to: clothes washers, dishwashers, and refrigerators, IRC P2903.5.

MECHANICAL PLAN:
9. Provide Manual J/S/D calculations for the forced air unit in accordance with M1401.3, M1601.1.
10. Provide whole-house mechanical ventilation, R303.4.

ELECTRICAL PLAN:
11. Bathrooms and laundry rooms require separate 20-amp circuits, E3703.4, E3901.6, E3703.3, 3901.8.
12. Correct code references to the 2006 IRC.
13. Specify faceplate grounding per E4001.11.1.
14. Specify tamper resistant receptacles per E4002.14.
15. All outlets shall be protected with combination-type arc-fault breakers (receptacles, lights, and smoke detectors), E3902.12.

If you have any questions please contact:
Clayton Trevillyan
520.837.4913
Residential Plan Review

Final Status

Task End Date Reviewer's Name Type of Review Description
05/14/2013 FERNE RODRIGUEZ OUT TO CUSTOMER Completed
05/14/2013 CPIERCE1 REJECT SHELF Completed