Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - TI
Permit Number - T13CM02209
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
05/08/2013 | MARTIN BROWN | FIRE | REVIEW | Approved | |
05/16/2013 | RONALD BROWN | BUILDING-COMMERCIAL | REVIEW | Approved | |
05/22/2013 | ROBERT SHERRY | WATER | REVIEW | Approved | |
05/22/2013 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | 1. Verify that the mixing valve specified for fixtures (e.g.PLC-2B) are listed as conforming to ASSE 1070. Reference: Sections 416.4 and 607.1.2, IPC 2012. 2. Revise the drains for the new 3-compartment sink (detail PSD-7/P6.1) to be independently routed to the indirect waste receptor and terminated with an air gap. Reference: Sections 801.2 and 802.1, IPC 2012. 3. Modify detail PSD-1/P6.1 to show that the installation of the open hub drains meets the requirements of Section 802.3.2, IPC 2006 with regard to the minimum projection above the floor (1") and show how the floor is to be made impervious to water at the point of penetration into the floor. 4. Provide accessible cleanouts in the island sink vent system to permit rodding of all portions of the vents located below the flood rim of the fixture. Reference: Section 916.3, IPC 2012. |
05/22/2013 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Denied | Provide electrical and balancing data for the fan that is to be replaced. Reference: Section 107.2.1, IBC 2012. |
05/30/2013 | RAY MAJUTA | ELECTRICAL-COMMERCIAL | REVIEW | Approved |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
06/11/2013 | FERNE RODRIGUEZ | OUT TO CUSTOMER | Completed |
06/11/2013 | CPIERCE1 | REJECT SHELF | Completed |