Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/WWM
Permit Number - T13CM01822
Review Name: RESIDENTIAL - BLDG/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/13/2013 | CLAYTON TREVILLYAN | BUILDING-RESIDENTIAL | REVIEW | Reqs Change | PLAN REVIEW COMMENTS Date: 6-13-13 Activity: T13CM01822 Address: 3437 N Wilson Applicant: Dan Taylor This letter reflects comments to be addressed. The purpose of this review is to verify compliance to the 2012 International Residential Code with local amendments. In order to facilitate a shorter back check time, we request that you please provide two complete sets of revised plans and calculations, along with a written response to each of the noted items indicating action taken. Other comment references may be derived from additional codes and standards adopted by The City of Tucson. All features have been checked only to the extent allowed by the submittals provided for review. All portions of this project are assumed to meet other departmental requirements, conditions, and concerns before permit approval. GENERAL REQUIREMENTS: 1. The City of Tucson has adopted the 2012 International family of codes. As of 1/01/2013 all code references should refer to the currently adopted code or appeal must be made to the Building Official for alternate code use. SITE PLAN: 2. Correct label on vehicular use area of building to garage instead of carport. FLOOR PLAN: 3. Show guardrail at second floor loft area, R312.1.2. 4. Specify nonabsorbent wall surface minimum 6' above the floor with cement, fiber-cement, or glass-mat board backing in tub/shower enclosures, R307.2, R702.4.2. FOUNDATION PLAN: 5. Specify size and location of footing for spiral staircase. STRUCTURAL / FRAMING PLAN: 6. Identify location of all braced wall lines, R403.1.6, R602.10.2.2.. 7. Justify braced wall panel sections for braced wall line located between existing building and new construction. 8. Relocate braced wall panel away from optional door between study and storage area. 9. Spiral staircase design must be signed, dated and wet-sealed by an engineer who is registered in Arizona. Note the requirement for a deferred submittal if the stair calculations will not be submitted with the plan review. 10. Remove expired detail for unvented roof design on sheet 5. Show insulation tight to roof deck per R806.5. 11. Justify joist sizes and spacing for roof top walk deck - minimum 40 psf live loading required. SECTIONS - DETAILS: 12. Correct joist and ledger size on detail 4 sheet 8 to coincide with framing specification. PLUMBING PLAN: 13. Show the size and location of cleanouts near the base of each vertical waste or soil stack, P3005.2. 14. Specify a minimum 1" water meter for the proposed demand according to the flow restrictions of the Tucson Water policy adopted 7/13/12 limiting the maximum demand for a 5/8" water meter to 11 IPC fixture units and a ¾" water meter to 28 IPC fixture units. Reference Tables P2903.6 and P2903.6 (1), IRC 2012. 15. Provide a water supply pressure loss calculation to include friction and elevation considerations, P2903.7. MECHANICAL PLAN: 16. Provide Manual J/S/D calculations for the forced air unit in accordance with M1401.3, M1601.1. ELECTRICAL PLAN: 17. Correct all mislabeled electrical code references. 18. Provide carbon monoxide alarms per R315. Alarms must be installed in residences with attached garages and/or fuel-fired appliances when any work is performed that requires a permit. 19. All outlets specified in section E3902.12 shall be protected with combination-type arc-fault breakers (not just bedroom outlets). 20. Specify faceplate grounding per E4001.11.1. 21. Specify tamper resistant receptacles per E4002.14. OUTDOOR LIGHTING CODE 22. Provide consistent information regarding lot size between outdoor lighting calculation and site plan lot area. 23. Correct lumen calculation based on a maximum of 55,000 allowable lumens per acre, OLC 3.1.2. INTERNATIONAL ENERGY CONSERVATION CODE: 24. Specify prescriptive insulation and fenestration values on sheets 6 & 7 per Table N1102.1.1/R402.1.1 or submit justified analysis. Simplified prescribed energy values for climate zone 2B: ceilings=R-38. 25. Specify high-efficacy lamps for at least 75% of all lighting fixtures, N1104.1. If you have any questions please contact: Clayton Trevillyan 520.837.4913 Residential Plan Review |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 06/20/2013 | CPIERCE1 | REJECT SHELF | Completed |