Permit Number: T13CM01787
Parcel: 13816001G

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T13CM01787
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/27/2013 MARTIN BROWN FIRE REVIEW Approved
10/02/2013 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Approved
10/08/2013 ROBERT SHERRY MECHANICAL-COMMERCIAL REVIEW Denied The programmable thermostat described in the 2012 IECC Compliance Notes does not include a set point overlap restriction or an automatic start capability. Reference: Sections C403.2.4.2 and C403.2.4.3.3, IECC 2012. [Second comment: A programmable thermostat does not necessarily provide the features required by the 2012 IECC; indicate the features provided by the proposed programmable thermostat that comply with the code requirements.] [Initial comment: Show that each rooftop unit has a thermostatic control that provides for off-hour and set-back control, automatic shutdown and start-up control and, if the control does not require manual changeover from the heating and cooling modes, restricts set point overlap. Reference: Sections C403.2.4.1, C403.2.4.2, C403.2.4.3, C403.2.4.3, C403.2.4.3.1, C403.2.4.3.2, and C403.2.4.3.3, IECC 2012.]
10/09/2013 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Denied The owner revision on sheet P1.1 calls for a ¾" hose bibb and a 2" indirect waste drain from the vicinity of appliance #34, a soft serve ice cream machine. Clarify the purpose of these additions. If the soft serve ice cream machine is to be water-cooled, show how the machine is to comply with the requirements of Section 929, IMC 2012, as amended by the City of Tucson.

Final Status

Task End Date Reviewer's Name Type of Review Description
10/14/2013 CPIERCE1 REJECT SHELF Completed