Permit Number: T13CM01402
Parcel: 12703559C

Address:
5515 E 5TH ST

Review Status: Completed

Review Details: COMMERCIAL - BLDG/FIRE/ZONING/ENG

Permit Number - T13CM01402
Review Name: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/12/2013 ERIC NEWCOMB BUILDING-COMMERCIAL REVIEW Denied 1. THE CALCULATIONS INDICATE THIS STRUCTURE WAS DESIGNED UNDER THE 2006 IBC. THE CITY OF TUCSON REQUIRES STRUCTURES DESIGNED AFTER JANUARY 1, 2013, TO USE THE 2012 IBC. AN AMENDMENT TO THE CODE REQUIRES UPLIFT CALCULATIONS TO USE A 110 MPH WIND SPEED (FOR MICROBURSTS). SEE CITY OF TUCSON AMENDMENT SECTION 1609.5.1.1. REVISE THE CALCULATIONS AS REQUIRED, AND MAKE ANY CHANGES TO THE DRAWINGS PER THOSE CALCULATIONS.
03/12/2013 BETH GRANT COMMERCIAL IMPACT FEE COMMERCIAL IMPACT FEE PROCESSING Passed
03/12/2013 JASON GREEN ENGINEERING REVIEW Approved
03/12/2013 KEN BROUILLETTE FIRE REVIEW Approved
03/12/2013 TERRY STEVENS ZONING REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
03/19/2013 SHANAE POWELL OUT TO CUSTOMER Completed