Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T13CM01360
Review Name: RESUBMITTAL
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
04/19/2013 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | The manufacturer's listing of the specified mixing valve does not allow the valve to be located at the water heater: "When used in an ASSE 1017 application at the hot water source, the Watts Thermostatic Mixing Valve Series LFMMV cannot be used by itself to control final temperature at fixtures where ASSE Standard 1016 or ASSE Standard 1070 listed devices are required". Reference: Section 303.2, IPC 2012. [Previous comment: Comment not addressed. Provide temperature mixing valves conforming to ASSE 1070 for the sinks used for hand washing (i.e. BS and HLAV). Reference: Section 416.5, IPC 2012.] |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
04/29/2013 | CPIERCE1 | APPROVAL SHELF | Completed |
04/29/2013 | CPIERCE1 | REJECT SHELF | Completed |