Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit Number: T13CM01360
Parcel: 13355231A

Review Status: Completed

Review Details: COMMERCIAL - TI

Permit Number - T13CM01360
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/04/2013 ROBERT SHERRY PLUMBING-COMMERCIAL REVIEW Denied 1. Comment not addressed. Provide temperature mixing valves conforming to ASSE 1070 for the sinks used for hand washing (i.e. BS and HLAV). Reference: Section 416.5, IPC 2012.
2. Comment not addressed. Show how the two floor sinks comply with Section 802.3, IPC 2012 with respect to location in an unventilated space and, how the floor sink located next to the relocated water heater has ready access.