Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Permit Number - T13CM01023
Review Name: COMMERCIAL - BLDG/FIRE/ZONING/ENG
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/26/2013 | MARTIN BROWN | FIRE | REVIEW | Approved | |
| 03/04/2013 | RAY MAJUTA | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
| 03/05/2013 | BETH GRANT | COMMERCIAL IMPACT FEE | COMMERCIAL IMPACT FEE PROCESSING | Approved | |
| 03/05/2013 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Denied | 1. SHEET CS-1; CODE CHECK (BUILDING CODE): THE CITY OF TUCSON CURRENTLY USES THE 2009 ICC/ANSI. REVISE THE DRAWING REFERENCE. 2. SHEET CS-1; CODE CHECK (EGRESS WIDTH): THE DRAWING INDICATES TABLE 1005.1 FOR EGRESS WIDTH. THE 2012 IBC REFERENCES SECTION 1005.3.2 FOR THAT WIDTH. REVISE THE DRAWING REFERENCE. 3. SHEET CS-1; CODE CHECK (EXIT EGRESS TRAVEL DISTANCE): THE DRAWING INDICATES TABLE 1016.1 FOR EXIT ACCESS TRAVEL DISTANCE. THE 2012 IBC REFERENCES TABLE 1016.2 FOR THAT DISTANCE. REVISE THE DRAWING REFERENCE. 4. SHEET CS-1; CODE CHECK (PLUMBING FIXTURES): THE DRAWING INDICATES TABLE 2900.1 FOR PLUMBING FIXTURE REQUIREMENTS. THE 2012 IBC REFERENCES TABLE 2902.1 FOR THE REQUIREMENT. REVISE THE DRAWING REFERENCE. 5. SHEET CS-1; CODE CHECK (PLUMBING FIXTURES): THE CALCULATION FOR THE NUMBER OF PLUMBING FIXTURES SHOULD BE 27.5 OCCUPANTS PER SEX. REVISE THE DRAWING. 6. SHEET CS-1; CODE CHECK: IT IS INDICATED THAT A DRINKING FOUNTAIN IS PROVIDED. IS THIS A HIGH/LOW FOUNTAIN, OR A SINGLE POINT OF USE DISPENSER? VERIFY AND INDICATE THE LOCATION ON THE PLAN. 7. SHEET S-1; GENERAL STRUCTURAL NOTES (FOUNDATIONS): NOTE 1 INDICATES FOUNDATION DESIGN BASED ON IBC TABLE 1804.2. THE 2012 IBC REFERENCES TABLE 1806.2 FOR PRESUMPTIVE SOIL BEARING VALUES. REVISE THE DRAWING REFERENCE. 8. SHEET S-3; FOUNDATION PLAN: DO THE TWO F1 FOOTINGS ON GRID 4 INTERFERE WITH ANY FOUNDATIONS ON THE EXISTING BUILDING? VERIFY AND PROVIDE A DETAIL AS REQUIRED. 9. STRUCTURAL CALCULATIONS (SCHNEIDER): THE COVER PAGE INDICATES THE 2006 IBC WAS USED IN THE FOUNDATION DESIGN. REVISE. 10. STRUCTURAL CALCULATIONS (SCHNEIDER): THE CITY OF TUCSON AMENDMENT TO THE 2012 IBC ADDS A NEW SECTION 1609.5.1.1 FOR UPLIFT DUE TO MICROBURST EFFECTS. REVISE ANY UPLIFT CALCULATIONS IF REQUIRED (MAY NOT BE NECESSARY DUE TO STAR BUILDING SYSTEMS USE OF 115 MPH WIND DESIGN). VERIFY. 11. GENERAL: THE CERTIFICATE OF OCCUPANCY ISSUED ON THIS PROJECT WILL ONLY INCLUDE THE 1450 SF ADDITION (5 OCCUPANTS). 12. GENERAL: PROVIDE WRITTEN RESPONSES TO ALL REVIEW COMMENTS. |
| 03/18/2013 | LOREN MAKUS | ENGINEERING | REVIEW | Approved | March 18, 2013 FLOODPLAIN USE PERMIT NO.: T13OT00224 ADDRESS: 1971 W McMillan St Tucson, Arizona 85705 PROPERTY OWNER: JIMP Holdings LLC 1971 W McMillan St Tucson, Arizona 85705 The applicant is authorized to use a portion of the FEMA Shaded Zone X 100-year floodplain per the Flood Insurance Rate Maps 04019C1669L, specifically described as: Parcel 106-10-1490; Northwest Tucson Industrial Park Lot 41 FW .657AC For the purpose of constructing an addition to an existing structure. The applicant agrees to comply with City of Tucson Floodplain and Erosion Hazard, and Watercourse Amenities, Safety and Habitat regulations, and are particularly bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Responsibility for renewal of this permit, if necessary, is with the applicant. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, UDC, or any other Federal, State, County, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under City of Tucson Floodplain and Erosion Hazard Regulations and Watercourse Amenities, Safety, and Habitat regulations require the issuance of an additional Floodplain Use Permit. The following 9 conditions apply to this permit: 1) This permit becomes invalid and is subject to additional floodplain review, if any required development changes the installation of the solar system or if there is any further disturbance within the floodplain and other than that outlined in this application. This floodplain use permit may be subject to conditions or restrictions designed to reduce or mitigate the potential damage or hazard to life or property resulting from the installation of the solar system within the regulatory floodplain, floodway or erosion hazard areas as determined by the project engineer and accepted by the City of Tucson. 2) Except as approved by the City Engineer prior to the start of construction, development under this permit shall not obstruct, retard or divert the existing flow of floodwaters from or to adjacent properties. 3) All work shall conform to the approved Details and General site plan sheets per DP12-0216, which are made part of this permit. 4) The finished floor elevation must meet or exceed the existing FFE of the existing structure as shown on the DP Package. 5) Within 5 (five) days of issuance of this permit, and through completion of the project, notification must be posted and maintained in a conspicuous place on the job site stating "CONSTRUCTION PROCEEDING UNDER REQUIREMENTS OF CITY OF TUCSON FLOODPLAIN USE PERMIT # T13OT00224 FOR INFORMATION PLEASE CALL 791-5550." 6) This Floodplain Use Permit and plans shall be kept in a readily accessible location on site at all times. 7) Any additional future disturbance of the floodplain shall have separate floodplain use permit applications submitted to this office for review and approval. 8) See the associated activity T13CM01023 9) This permit is specific to the improvements for 1971 W McMillan St as indicated on the approved plans. It shall not apply to any other structure or property, whether attached or unattached, not specified under this permit. Renewal of this permit will require a new application, review and approval of that application by the City of Tucson, Development Services Department, Engineering Division. This permit may be renewed for up to one year, in the absence of Registered Plant authorization, at the sole discretion of the City Engineer or designated representatives. This Floodplain Use Permit will be automatically revoked and becomes invalid if conditions are not complied with, as set forth in this permit. APPLICANT NAME: Stephen Moos ADDRESS: 5662 E 13th St Tucson, Arizona 85711 PHONE: 520-861-4833 Owner: JIMP Holding LLC ADDRESS: 1971 W McMillan St Tucson, Arizona 85705 PHONE: 520- 293-7818 (EXPIRATION DATE) Month: 03 Day: 18 Year: 2014 SIGNATURE OF APPLICANT DATE The applicant is authorized by the City Engineer to receive a floodplain use permit subject to the above referenced conditions and restrictions. |
| 03/21/2013 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Passed |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 03/26/2013 | FERNE RODRIGUEZ | OUT TO CUSTOMER | Completed |