| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/15/2013 | ANY | ENGINEERING | REVIEW | Active | |
| 02/15/2013 | ANY | BUILDING-RESIDENTIAL | REVIEW | Active | |
| 02/21/2013 | STEVE SHIELDS | ZONING | REVIEW | Denied | P&DS TRANSMITTAL FROM: Steve Shields, Lead Planner PROJECT: 2302 E. Mitchell Street T13CM00916 Proposed Garage addition TRANSMITTAL: March 8, 2013 COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1). 1. This site is located in the R-1 zone (UDC 4.7.8). A single-family residence (SFR) is a permitted use in this zone (Table 4.8-2). See Use-Specific Standards 4.9.7.B.5 - 9. 2. The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure's wall facing each interior property line (Table 6.3-2.A). Proposed setback to the east property line is 3'-0". 3. The minimum setback to the front street perimeter property line is the greater of twenty (20) feet, or one and one-half (1 ½) the height of the proposed wall ((UDC 6.4.5.C.1.a). The proposed front street setback is 18'-0" |
| 02/21/2013 | SSHIELD1 | NPPO | REVIEW | Passed |