Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T13CM00607
Review Name: RESUBMITTAL
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
03/05/2013 | RAY MAJUTA | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
03/18/2013 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Denied | Comment not resolved; provide an approved engineering analysis of the specific occupancy of rooms 111 and 122 with supporting statistical data or use the occupant density value for the telephone/data entry areas shown in Table 403.3, IMC 2012. [Original comment: The occupant load used to calculate the required ventilation is not necessarily the same as the occupant load used for calculating exiting requirements. The occupant load used for calculating the minimum required ventilation is to be based on Table 403.3, IMC 2012 (e.g. telephone/data entry has an occupancy rate of 60 people pre 1,000 square feet) or an approved engineering analysis of the specific occupancy type with supporting statistical data. Reference: Section 403.3, IMC 2012.] |
03/18/2013 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | Verify that the specified trap primer can successfully deliver water to a trap located approximately 70-feet from the distribution unit. [Original comment: Provide protection of the trap seals for floor drain FD-2. Reference: Section 1002.4, IPC 2012.] |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
03/29/2013 | SHANAE POWELL | OUT TO CUSTOMER | Completed |
03/29/2013 | CPIERCE1 | REJECT SHELF | Completed |