Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL - BLDG/ZONING-WALKTHRU
Permit Number - T13CM00553
Review Name: RESIDENTIAL - BLDG/ZONING-WALKTHRU
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/01/2013 | STEVE SHIELDS | ZONING | REVIEW | Approved | P&DS TRANSMITTAL FROM: Steve Shields, Lead Planner PROJECT: Attached carport TRANSMITTAL: April 1, 2013 COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1). The minimum driveway length to the edge of a sidewalk for a carport is nineteen (19) feet (UDC Section 6.4.5.C.2.b.1). The minimum driveway length for a carport is eighteen feet to the property line (UDC Section 6.4.5.C.2.b.1.a & b). Proposed driveway length to the sidewalk is 4'. Proposed driveway length to the northeast street property line is 0.0'. |
| 04/01/2013 | SSHIELD1 | NPPO | REVIEW | Passed | |
| 04/01/2013 | STEVE SHIELDS | ZONING | REVIEW | Approved | P&DS TRANSMITTAL FROM: Steve Shields, Lead Planner PROJECT: Attached carport TRANSMITTAL: April 1, 2013 COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1). The minimum driveway length to the edge of a sidewalk for a carport is nineteen (19) feet (UDC Section 6.4.5.C.2.b.1). The minimum driveway length for a carport is eighteen feet to the property line (UDC Section 6.4.5.C.2.b.1.a & b). Proposed driveway length to the sidewalk is 6'. Proposed driveway length to the north street property line is 2.0'. |
| 04/01/2013 | STEVE SHIELDS | ZONING | REVIEW | Approved | FROM: Steve Shields, Lead Planner PROJECT: T13CM00553 Attached carport TRANSMITTAL: May 15, 2013 (Revised) COMMENTS: the following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1). The minimum driveway length to the edge of a sidewalk for a carport is nineteen (19) feet (UDC Section 6.4.5.C.2.b.1). The minimum driveway length for a carport is eighteen feet to the property line (UDC Section 6.4.5.C.2.b.1.a & b). Proposed driveway length to the sidewalk is 4'. Proposed driveway length to the northeast street property line is 0.0'. The minimum setback to the front street perimeter property line is the greater of twenty (20) feet, or one and one-half (1 ½) the height of the proposed wall ((UDC 6.4.5.C.1.a). Proposed setback to the front street perimeter property line is 2'. |
| 06/24/2013 | JASON GREEN | ENGINEERING | REVIEW | Approved | |
| 06/24/2013 | KEN VAN KARSEN | BUILDING-RESIDENTIAL | REVIEW | Approved |