Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL - TI
Permit Number - T13CM00187
Review Name: COMMERCIAL - TI
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
01/11/2013 | LOREN MAKUS | ENGINEERING | REVIEW | Approved | |
01/15/2013 | STEVE SHIELDS | ZONING | REVIEW | Denied | PDSD TRANSMITTAL FROM: Steve Shields Lead Planner PROJECT: U-Haul @ 6755 E. Golf Links Road T13CM00187 Building Plan (1st Review) TRANSMITTAL DATE: January 15, 2013 1. The building plan has been reviewed by Zoning Review Section but cannot approve the plan until all zoning comments or concerns have been addressed. 2. Zoning can not approve the building plan until a development plan has been approved. 3. Zoning will re-review the building plan on the next submittal to insure compliance with the approved development plan. Additional comments may be forthcoming. If you have any questions about this transmittal, please contact me at Steve.Shields@tucsonaz.gov or (520) 837-4956 |
01/18/2013 | ERIC NEWCOMB | BUILDING-COMMERCIAL | REVIEW | Denied | 1. SHEET T1; GOVERNING BUILDING CODES: THE ICC/ANSI EDITION USED BY THE CITY OF TUCSON IS 2009. REVISE NOTE. 2. SHEET T1; BUILDING CODE ANALYSIS: TABLE 2902.1 OF THE IBC REQUIRES A HIGH/LOW DRINKING FOUNTAIN OR A SINGLE POINT-OF-USE WATER DISPENSER. PROVIDE. 3. SHEET T1; BUILDING CODE ANALYSIS: THE EXIT ACCESS TRAVEL DISTANCE REFERENCES TABLE 1016.1. REVISE TO 1016.2. 4. SHEET T3; MOUNTING HEIGHTS: A NOTE INDICATES THE 2003 EDITION OF THE ICC/ANSI A117.1. REVISE. 5. SHEET A3: THE CITY OF TUCSON REQUIRES ALL LETTERING (UPPER AND LOWER CASE) TO BE A MINIMUM OF 3/32" IN HEIGHT. REVISE THE ROOF PLAN, FLOOR PLAN, AND ELEVATIONS 'B'. 6. SHEET A3; ROOF PLAN 'B': MOVE GENERAL NOTE E SO THAT THE NOTE IS LEGIBLE. 7. SHEET A3; ROOF PLAN 'B' (KEYNOTES): NOTES 75, 77, AND 79 WERE NOT LOCATED ON THE PLAN. VERIFY. 8. SHEET A3; FLOOR PLAN 'B': A NOTE REFERENCES THE 2010 ADA STANDARD FOR ACCESSIBLE DESIGN. REVISE THE NOTE TO THE ICC/ANSI A117.1-2009. 9. SHEET A3; FLOOR PLAN 'B': ON GRID A BETWEEN GRIDS 2 AND 3, AND ON GRID 1, A WALL TYPE X IS INDICATED. NO WALL TYPE X WAS LOCATED IN THE SCHEDULE. VERIFY. 10. SHEET A3: ADD A NOTE ON THIS SHEET TO REFERENCE SHEET A6 FOR THE DOOR AND WINDOW SCHEDULE. 11. SHEET A3; ELEVATIONS 'B': NOTES 38 AND 79 WERE NOT LOCATED ON THE ELEVATIONS. VERIFY. 12. SHEET A3; ELEVATIONS 'B': COLOR NOTES A, B, D, E, F, G, J, K, L, M, O, AND P WERE NOT LOCATED ON THE ELEVATIONS. VERIFY. 13. SHEET A3.1; BUILDING SECTIONS 1 AND 3: THE WALL PANEL TYPES ARE NOT INDICATED ON THE SECTIONS (THE DIAMOND NOTATION CONTAINS NO REFERENCE). VERIFY. 14. SHEET A3.1 (BUILDING SECTION 1); SHEET A8 (DETAIL 10): BUILDING SECTION 1 INDICATES A DETAIL 10/A8 AT THE ROOF EDGE, BUT THAT DETAIL INDICATES 'NOT USED'. CLARIFY. 15. SHEET A3.1; BUILDING SECTION 3: THE DETAIL AT THE BASE OF THE WALL (ON THE LEFT) INDICATES 2A&B/A3.1. IS THIS CORRECT? 16. SHEET A6: THE CITY OF TUCSON REQUIRES ALL LETTERING (UPPER AND LOWER CASE) TO BE A MINIMUM OF 3/32" IN HEIGHT. REVISE THE PART LIST. 17. SHEET A7; FLOOR PLAN 1: A NOTE INDICATES THIS PLAN "IS FOR ILLUSTRATION PURPOSES ONLY". THIS PLAN SHOULD INDICATE EXACTLY WHAT IS ON SHEET A3. REVISE. 18. SHEET S3.1; HEADER SCHEDULE: THE CITY OF TUCSON REQUIRES ALL LETTERING (UPPER AND LOWER CASE) TO BE A MINIMUM OF 3/32" IN HEIGHT. REVISE THE SCHEDULE. 19. STRUCTURAL CALCULATIONS: PROVIDE A KEY PLAN IN THE CALCULATIONS INDICATING NEW BEAMS (PURLINS) AND COLUMNS. 20. GENERAL: PROVIDE WRITTEN RESPONSES TO ALL REVIEW COMMENTS. |
01/25/2013 | LEERAY HANLY | MECHANICAL-COMMERCIAL | REVIEW | Approved | |
01/25/2013 | LEERAY HANLY | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
01/25/2013 | LHANLY1 | WATER | REVIEW | Passed | |
01/25/2013 | LEERAY HANLY | PLUMBING-COMMERCIAL | REVIEW | Passed | |
01/25/2013 | LHANLY1 | WWM | REVIEW | Passed | |
01/29/2013 | KEN BROUILLETTE | FIRE | REVIEW | Approved |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
02/05/2013 | CPIERCE1 | REJECT SHELF | Completed |