Plan Number: T12SE00095
Parcel: Unknown

Review Status: Completed

Review Details: REZONING - IPC

Plan Number - T12SE00095
Review Name: REZONING - IPC
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
10/15/2012 STEVE SHIELDS ZONING REVIEW Completed PDSD TRANSMITTAL

TO: Rezoning Division
Re: Acceptance of Information for Plan Compliance (IPC)

FROM: Steve Shields
Lead Planner

PROJECT: AT&T Communication Site
McCormick Park - Columbus & Blacklidge
Special Exception - SE-12-95

TRANSMITTAL: October 15, 2012

The proposed Communications site, located on parcel 110-05-327C zoned R-1 falls under the Special Exception Land Uses, Sec. 2.3.4.3.A.1, Commercial Services Use Group, Sec. 6.3.5, Communications "17", limited to wireless communication towers and antennae, subject to: Sec.
3.5.4.20.B, .C, and .G

Development designator "17" requires or allows the following:

Minimum site area = 7,000 Sq. Ft.
Site area proposed = 613,744.
Floor Area Ratio (FAR) = 0.50
Floor Area (FA) Allowed = Not provided on plan
Floor Area (FA) Proposed = Not provided.
Lot coverage allowed = 70%
Lot coverage proposed = Not provided.
Maximum building height allowed = 25 feet
Building height proposed = Tower height 68', building height 10-0"
Interior perimeter yard indicator = BB

1. Provide documentation that shows how the requirements of LUC Section 3.5.4.20.G.1.b are met.

2. Provide a copy of the last approved site plan.

3. The submitted plan, showing the communication site is acceptable to continue the review for the zoning examiner's report

If you have any questions about this transmittal, please call Steve Shields, (520) 836-4956 or email Steve.Shields@tucsonaz.gov.
10/17/2012 LAITH ALSHAMI ENGINEERING REVIEW Completed
10/22/2012 MPADILL1 COMMUNITY PLANNING REVIEW Denied PLANNING & DEVELOPMENT SERVICES DEPARTMENT
SE-12-95 AT&T - Columbus Blvd.
General Plan and Arcadia - Alamo Area Plan
10/18/12 msp

This proposal is for a special exception use in the R-1 residential zone to allow a 68 foot wireless communication facility in the form of a stealth monopalm/pine. The site is at 2900 N. Columbus Blvd., located approximately 750 feet southeast from the intersection of Fort Lowell Road and Columbus Blvd.

At this time no further review will be conducted as the submittal is (incomplete) of insufficient information to continue.




f:/sharedri/UPDfiles/DevRev/caserev/SP-Excpt/SE 11-12/SE-12-95 AT&T - Columbus Blvd.doc
10/22/2012 KEN BROUILLETTE FIRE REVIEW Approved