Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - OVERLAY ZONE REVIEW
Permit Number - T12SA00195
Review Name: RESUBMITTAL - OVERLAY ZONE REVIEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/07/2012 | JOE LINVILLE | LANDSCAPE | REVIEW | Approv-Cond | The Landscape Section recommends approval subject to resolution of the remaining comments on the Development Plan and recording of the proposed Trail/Drainage easement. |
| 08/08/2012 | PAUL MACHADO | ENGINEERING | REVIEW | Denied | To: Hubbard Engineering DATE: August 8, 2012 1840 S. Stapley Dr. Ste 137 Mesa, Arizona 85204 Subject: Sante Tucson, 2040 N. Wilmot Rd. W.A.S.H. overlay review T12SA00195 (Third Review) T14S, R15E, Section 06 RESUBMITTAL REQUIRED: Watercourse Amenities, Safety and Habitat (W.A.S.H) The Watercourse Amenities, Safety and Habitat (W.A.S.H.) cannot be approved as submitted. Please address the following review comments prior to the next submittal. W.A.S.H: 1. Please include a response letter to the comments along with the corrected copies of the W.A.S.H submittal. 2. The project is subject to the provisions of the Watercourse, Amenities, Safety, and Habitat Ordinance, TCC Ch. 29 Art. VIII, Sec. 29-17. No concrete is allowed in the W.A.S.H. designated wash. Greater detail is also needed then what was shown previously in order review and build the proposed solution that will satisfy the comment. 3. A meeting between the designer and the reviewer (owner/developer is welcome to attend) is suggested prior to the re-submittal. The meeting can be in conjunction with the meeting to go over the development plan comments. Contact Paul P. Machado @ 837-4932 or Patricia Gehlen @ 837-4919 to set up a meeting with me and/or any of the other reviewers. Flood Plain Use Permit: 2. The FPUP will be approved with the Development Package and the W.A.S.H. review. If you have any questions, I can be reached at 837-4932 or Paul.Machado@tucsonaz.gov Paul P. Machado Senior Engineering Associate City of Tucson - Planning and Development Services Department 201 N. Stone Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 837-4932 office (520) 879-8010 fax C:/2040 N. Wilmot Rd_Wash Overlay |
| 08/08/2012 | PATRICIA GEHLEN | ZONING-DECISION LETTER | WRITE DECISION LETTER | Denied | The review has been completed. Please make the necessary corrections and resubmit the plans and other documents as required. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 09/12/2012 | FERNE RODRIGUEZ | OUT TO CUSTOMER | Completed |