Permit Number: T12SA00195
Parcel: 133165760

Address:
2040 N WILMOT RD

Review Status: Completed

Review Details: LUCAPPS - OVERLAY ZONE REVIEW

Permit Number - T12SA00195
Review Name: LUCAPPS - OVERLAY ZONE REVIEW
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/19/2012 STEVE SHIELDS ZONING REVIEW Approved PDSD TRANSMITTAL

FROM: Steve Shields
Lead Planner

PROJECT: 2040 N. Wilmot Road
T12SA00195
Overlay Zone Application - Wash

TRANSMITTAL DATE: June 19, 2012

COMMENTS: Please resubmit revised drawings along with a response letter, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. The Zoning Review Section approves the overlay review for this project. However, should there be any changes requested by other CDRC members, the Zoning Review Section approval is void, and we request copies of the revised development plan to verify that those changes do not affect any zoning requirements.


If you have any questions about this transmittal, please contact Steve Shields, (520) 837-4956 or Steve.Shields@tucsonaz.com

RESUBMITTAL OF THE FOLLOWING IS REQUIRED:
06/27/2012 JOE LINVILLE LANDSCAPE REVIEW Denied 1) Revise the ERR to incorporate any disturbance for the proposed bleed pipe.

2) Revise the Development and landscape plans to include the path and landscaping for the Rose Hill Wash Greenway.
TCC 26-5.2.1, TCC 29-17.(a).3, DS 2-01.3.9.I

3) Provide a 25' wide easement for Rose Hill Wash Greenway. The required maintenance access easement may be co-located in the Greenway.TCC Sec 26-8 (f)

4) Revise the development plan to identify and delineate the Regulated Areas (50' study area and channel) and the Protected Riparian Area on the property. The boundary of the Regulated Area and the Protected Riparian Area should be clearly depicted on applicable submittal documents.
DS 9-06.2.4

5) Revise General Note 5 on sheet 2 to reference the
WATERCOURSE AMENITIES, SAFETY AND HABITAT (WASH) regulations. DS 2-01.3.7

6) If the property includes Protected Riparian Area add a note stating that the project is designed to comply with Development Standard 9-06.0., specifying all lots impacted and including a total (area) for the regulated area and the Protected Riparian Area. DS 2-01.3.7.A.6

7) Add the following note to the Development Plan: All new onsite and offsite trails or paths constructed in conjunction with this project will be constructed in accordance with approved plans. Construction plans will be subject to the review and approval of the City’s Parks and Recreation Department, and, if requested, Pima County Natural Resources, Parks and Recreation. DS 2-01.3.7.F

8) Where the Protected Riparian Area is on property that remains under the ownership of a single person or entity following the development, the Protected Riparian Area shall be protected through a conservation or public easement or other legal restriction upon further development.
DS 9-06.2.6.D
07/02/2012 PAUL MACHADO ENGINEERING REVIEW Denied DATE: July 3, 2012 FROM: Paul Machado
Engineering Dept.
TO: Patricia Gehlen
CDRC

SUBJECT: Sante of Tucson
T12SA00195, T14S, R15E, SECTION 06

RECEIVED: Overlay Zone Review (WASH) on Rose Hill Wash - Sante of Tucson

The subject submittal has been reviewed. We offer the following comments:

1. The project is impacted by the Rose Hill Wash. The Mitigation Report shall address all the washes that impact the project in accordance with requirements of Development Standard 2-13.0.
2. Revise the dev plan to include the path and landscaping for the Rose Hill Wash Greenway per TCC 26-5.2.1, TCC 29-17.(a).3, DS 2-01.3.9.I
3. The bleed off pipe shown on the plans that draining into the riparian area will need to have scour protection at the outlet. How is this proposed to be done in a W.A.S.H. wash?
4. A 25' wide easement for Rose Hill Wash Greenway is required. The maintenance easement may be located in the Greenway. TCC Sec 26-8 (f)
5. Show the regulated Areas (50' study area) and the Protected Riparian Area on the property and shall comply with this Development Standard. DS 9-06.2.4
6. Show the erosion hazard setback lines on the exhibits to clarify their location relative to the resource areas (Tucson Code 29-17.b.3.).
7. Determine, in the hydrology/hydraulic study, the Atterbury banks and the 50' study area and show this information on the Exhibits. Please be advised that if the wash banks are not defined, the 10-year floodplain limits can be used as the wash banks and the study area can be measured from the 10-year floodplain limits.
8. Detention/Retention basins are not allowed in the floodplain designated limits.
9. Include in the text and show on the appropriate exhibits the required fencing around ERZ and W.A.S.H areas that are not proposed to be disturbed, to prevent accidental encroachment on these areas.
10. Considering the requirements of the W.A.S.H. Ordinance and the ERZ requirements, how do you propose accommodating for wash maintenance access as required by Section 1.5.1 of the Drainage Manual.


Prepare a detailed response that explains the revisions that were made and references the exact location in the submittal where the revisions were made.


RESUBMITTAL REQUIRED: Revised Mitigation Report including the Hydrology submittal

2040 N. Wilmot Rd - WASH Overlay
07/03/2012 PATRICIA GEHLEN ZONING-DECISION LETTER WRITE DECISION LETTER Denied COMMUNITY DESIGN REVIEW COMMITTEE
DEVELOPMENT SERVICES

July 3, 2012

Forest Weier
The Planning Center
110 South Church Avenue #6320
Tucson, Arizona 85701

Subject: T12SA00195 WASH Overlay Zone for 2040 North Wilmot Road (DP12-0062)

Dear Forest:

Your submittal of June 4, 2012 for the above project has been reviewed by the Community Design Review Committee and the comments reflect the outstanding requirements which need to be addressed before approval is granted. Please review the comments carefully. Once you have addressed all of the comments, please submit the following revised documents and a DETAILED cover letter for each agency explaining how each outstanding requirement has been addressed:

ALL BLUELINES MUST BE FOLDED

2 rolled copies Revised Overlay Zone submittal package as detailed in the on line comments.









Should you have any questions, please call me at 837-4919.

Sincerely,


Patricia Y. Gehlen
CDRC Manager

All comments for this case are available on our website at http://www.ci.tucson.az.us/dsd/

Final Status

Task End Date Reviewer's Name Type of Review Description
07/25/2012 CPIERCE1 OUT TO CUSTOMER Completed