Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T12SA00143
Parcel: 12201027B

Review Status: Completed

Review Details: SIGN CODE APPEALS AND ADVISORY BOARD

Permit Number - T12SA00143
Review Name: SIGN CODE APPEALS AND ADVISORY BOARD
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/07/2012 SUE MONTES START APPLICATION ACCEPTED Completed
05/18/2012 DAVID RIVERA ZONING REVIEW Completed From: David Rivera, Principal Planner
Zoning Review Section

Date: May 30, 2012

Project: Tucson Botanical Gardens, New Sign/Wall

Address: 2150 N Alvernon Way

Site plan has been review by Zoning for variance comments. At this time zoning cannot approve the site plan until the following comments are addressed by making changes to the plans that demonstrate compliance or variances for the items listed below must be approved through a Board of Adjustment variance process.

Variance Comments: This review was for variance comment only.

(The Zoning Review Section has no comments related the requested variance for the sign.)

A. However the Zoning Review Section does refer the proposal to the Board of Adjustments for reduced building setbacks.

LUC Section 3.2.5.2.H, the maximum height of a wall or fence within a perimeter yard is six (6) feet; however, the wall or fence may be higher than six (6) feet, but no higher than ten (10) feet, if: (See Illustration 3.2.5.2.H.)

1. At least seventy-five (75) percent of the area above six (6) feet in height is left unobstructed and open through the use of architectural elements, such as arches, columns, or wrought iron, or

2. Part of, or located on top of, a retaining wall no higher than ten (10) feet measured from design grade and no higher than six (6) feet measured from the top of the retaining portion of the wall, or

3. A greater height is required through the rezoning process or the Special Exception Land Use process, or

The proposed steel fence includes two Columns at the entrance and is proposed at a maximum height of 14'-1" which includes an illuminated lamp on each column. The Arch at the entrance is proposed at a maximum height of 18'-2.37". A Variance for the proposed height of 8'-2.37' above the allowed ten (10) feet is required.

B. Minimum Height Clearance along access lanes.

Luc Section 3.3.6.5 Additional Access Lane and Parking Area Access Lanes (PAAL) Design Criteria

3.3.6.5.B. Height Clearance. The minimum height clearance along access lanes and PAALS is fifteen (15) feet. Exception. The minimum height clearance within parking garages may be less than fifteen (15) feet as permitted by the City's adopted Building Code.

C. It is not clear from the documents submitted for review whether or not the building setback for the steel fence/columns has been met. The drawings do not include existing and future roadway dimensions from the existing or future back of curb location based on the Mayor and Council Approved Major Streets and Routes Map. The following comment is made based on the assumption that the setback from the existing or future back of curb cannot be met.

1. The setback requirement for a building setback along the Alvernon Way street frontage is based on the greatest of 21 feet or the height of the structure. The required setback for this proposal from the existing and/or future back of curb location is 21 feet, LUC section 3.2.6.5.B, ADT 1,000+. If the 21 foot setback cannot be met the applicant must apply for a Board of Adjustment variance for the proposed building setback.

2. If the walls do not meet the minimum setbacks from the back of curb it is likely that the walls may also interfere with the sight visibility triangles. Until the correct right of way information is included on the plans it is assumed that a DSMR for Development Standard 3-01.5.1.A, (Lines of Sight Encroachment/SVT ) will be required.
05/18/2012 JOSE ORTIZ DOT TRAFFIC REVIEW Approved
05/24/2012 MPADILL1 COMMUNITY PLANNING REVIEW Completed The Grant-Alvernon Area Plan provides Guideline #10, as a planning tool, which states the following: - Design signs to be compatible with the landscape plan and reflect the architectural style or theme of the proposed development.
05/31/2012 SUE MONTES AGENDA AGENDA TO BCC Completed
05/31/2012 SUE MONTES LEGAL AD PREPARE LEGAL AD Completed
05/31/2012 SUE MONTES FIELD TRIP FIELD TRIP Completed
05/31/2012 SUE MONTES LEGAL AD LEGAL AD TO PAPER, MAIL LEGAL AD Completed
06/13/2012 SUE MONTES REPORT BEGIN STAFF REPORT Completed
06/13/2012 SUE MONTES HEARING SET HEARING DATE Completed
06/13/2012 SUE MONTES REPORT STAFF REPORT TO ADMINISTRATOR Completed
06/13/2012 SUE MONTES REPORT DISTRIBUTE STAFF REPORT Completed
06/13/2012 SUE MONTES REPORT POWERPOINT PRESENTATION COMPLETE Completed
06/13/2012 SUE MONTES REPORT HEARING DATE Completed
06/13/2012 SUE MONTES REPORT HAVE IT UPLOAD PRESENTATION Completed
06/20/2012 SUE MONTES DECISION PREPARE SUMMARIES AND DECISION LETTERS Completed
06/20/2012 HEATHER THRALL SIGNS SIGN CODE REVIEW Completed
06/20/2012 SUE MONTES IT TECH REQUEST SET UP OF EQUIPMENT Completed
06/20/2012 SUE MONTES DECISION EMAIL/MAIL DECISION LETTERS Completed