Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: T12SA00043
Parcel: 10705121A

Review Status: Completed

Review Details: SIGN - HISTORIC LANDMARK

Permit Number - T12SA00043
Review Name: SIGN - HISTORIC LANDMARK
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/02/2012 HEATHER THRALL START APPLICATION ACCEPTED Completed
03/05/2012 JOSE ORTIZ DOT TRAFFIC REVIEW Approved No issues with TDOT Traffic - Approved
03/05/2012 SMONTES1 URBAN PLANNING REVIEW Approved Community Planning Staff has no objection to the refurbishing of the existing monument sign installed in 1958 at the West Ward Winds Lodge (Gospel Rescue Mission), to its original colors, design and material, as proposed under HLS (sign) Treatment Plan under case T12SA00043.
03/05/2012 SMONTES1 HPZAB COMMENT DUE DATE IS SET DUE DATE Passed
03/07/2012 GLENN MOYER TECH DETERMINATION TECH GUIDELINE DETERMINATION Approved
03/07/2012 HEATHER THRALL TECHNICAL GUIDELINE REVIEW TECHNICAL GUIDELINE REVIEW; EMAIL RESULT Completed SUBJECT SITE: 707 W. Miracle Mile, was Wayward Winds Motel - recent reuse as shelter for Gospel Rescue Mission

PROJECT: Historic Landmark Sign (HLS) Review

FOR: Existing Detached Nonconforming Pole sign consists of 1 large cabinet with irregular shape, with full extents of the sign at 18.83' by 9.5' = 178 sqft total, located off Miracle Mile frontage.

PROPOSAL: consists of a Treatment Plan to " restore the sign to it's 1958 appearance... by reconstructing lost channel script and restoring the colored neon and upgrading electrical and painting the color to original configuration." The proposal also calls for an "adaptive- reuse" of the oval panel at the top of the sign cabinet (approximately 24 square feet) for the new tenant on the premises, the "Gospel Rescue Mission".

This review encompasses Sections 3-70.D Technical Guidelines and 3-70.E - Performance Requirements for HLS Criteria.

Technical Guidelines - The sign meets all 5 of these criteria:
3-70.D.1. contains exposed neon lighting
3-70.D.2. uses materials representative of it's period of construction (except for adaptive reuse panel, which is lexan and vinyl)
3-70.D.3. sign is non-rectangular in shape
3-70.D.4. sign is a detached freestanding pole sign
3-70.D.5. sign is structurally safe per contractor's assessment.

Performance Requirements - The sign does meet these criteria outlined below:
3-70.E.1.A. Restoration and repair is consistent with documented appearance prior to 1961 (per permit)
3-70.E.1.B NA (Not transitional HLS)
3-70.E.1.C NA (not replica HLS)
3-70.E.1.D Restoration will not add typographical elements resulting in increase in size of restored sign.
3-70.E.2 - Adaptive Reuse:
3-70 E.2.A - NA - not replica
3-70 E.2.B - defer to TPCHC
3-70 E.2.C - defer to TPCHC
3-70 E.3 NA - no Relocation planned
3-70 E.4 NA - not replica HLS
3-70 E.5 - Main sign structure has not been altered or removed per 3-96.C.1.

Overview: The Treatment Plan calls for thre removal of the main sign cabinet, refurbishing the cabinet, manufacturing and installing the channel letters, adding neon in colors representative of it's original condition, and adaptively re-using a portion of the panel with similar material -albeit modern material - to what was used when originally permitted. In sign cabinet would then be reinstalled (support poles to remain in place).

PERMITTING PROCESS:
Should the TPCHC approve the proposal and designate this sign as an HLS, the work involved in it's restoration is equivalent to a sign repair permit at minimum. To obtain a sign repair permit requires staff to review structural and electrical drawings and calculations that support the method of assembly and the electrical assembly, a sign permit application and site plan demonstrating the position of the sign with Sight Visibiltiy Triangles, property lines and sebacks from the face of street curb called out.

Should there be any questions on this review, please contact Heather.Thrall@tucsonaz.gov or 837-4951.
03/07/2012 SUE MONTES TPCHC MTG NOTIFICATION TPCHC MEETING - NOTIFY Completed
03/22/2012 SUE MONTES SCHEDULE TPCHC MEETING SCHEDULE T-PCHC MTG Completed
04/12/2012 FRANK PODGORSKI HPZ ADVISORY BOARD DECISION REC'D HPZ ADVISORY BOARD DECISION Completed -
04/20/2012 HEATHER THRALL DSD DIRECTOR DECISION/RECOMMENDATION PDSD DIRECTOR DECISION/RECOMMENDATION Completed Approved.

Character defining features:
Shape of sign
Wayward Winds lodge channel letters
Original font and typography
original blue and red/orange/yellow paint colors
original color of the neon lighting

Character Defining Text:
Wayward Winds Lodge
09/13/2012 HEATHER THRALL PUBLIC HEARING: TPCHC MEETING TPCHC MEETING Completed TPCHC plans review subcommittee met 4/12/2012