Review Details: PIA - SUBMITTAL
Plan Number - T12PI00014
Review Name: PIA - SUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/15/2012 | BESPINO1 | UTILITY CLEARANCES | COT STREETS DIVISION | Approved | |
| 11/15/2012 | BESPINO1 | UTILITY CLEARANCES | COT WATER NEW DEVELOPMENT | Approved | |
| 11/15/2012 | BESPINO1 | UTILITY CLEARANCES | PC WASTEWATER MGMT | Approved | |
| 11/15/2012 | BESPINO1 | UTILITY CLEARANCES | QUEST COMMUNICATION | Approved | |
| 11/15/2012 | BESPINO1 | UTILITY CLEARANCES | TUCSON ELECTRIC POWER CO | Approved | |
| 11/15/2012 | BESPINO1 | UTILITY CLEARANCES | COX COMMUNICATION | Approved | |
| 11/15/2012 | BESPINO1 | UTILITY CLEARANCES | SOUTHWEST GAS CORP | Approved | |
| 11/15/2012 | BESPINO1 | UTILITY CLEARANCES | EL PASO NATURAL GAS | Approved | |
| 11/15/2012 | BESPINO1 | UTILITY CLEARANCES | KINDER MORGAN ENERGY | Approved | |
| 11/21/2012 | JOSE ORTIZ | DOT TRAFFIC | REVIEW | Approv-Cond | ACTIVITY NUMBER: T12PI00014 PROJECT NAME: SEARS Blvd: Bilby to Valencia PROJECT REVIEWER: Matthew Geweke, Traffic Eng Tech Conditional Acceptance: Traffic Engineering recommends conditional approval of the PIA Plan; therefore a revised PIA Plan is not necessarily required for re-submittal but the following items must be revised or added to the plan. Just an email response with an exchange of PDF's is acceptable in lieu of a re-submittal. 1. See redlines on the submitted drawings and address the additional redline comments on Sht. 13 2 See Traffic Eng note attached to the accompanying cover letter. If you have any questions, I can be reached at 791-4259 x76665 or email Matthew.Geweke@tucsonaz.gov |
| 11/28/2012 | GARY WITTWER | DOT LANDSCAPE | REVIEW | Denied | There appears to be some vegetation along the existing roadway. Please address the Native Plant Preservation Ordinace. Let me know if you have questions. Will the median island at the school be concrete? Will it be planted. We do not want an area that we have to maintain. |
| 12/13/2012 | RICHARD LEIGH | DOT ENGINEERING | REVIEW | Denied | December, 12, 2012 SUBJECT: Sears Blvd., Bilby Rd to Valencia Rd. Roadway Reconstruction, Public Improvements, PIA T12PI0014 PROJECT REVIEWER: David Wostenberg/Richard Leigh, DOT, Permits and Codes Section RESUBMITTAL REQUIRED: Permits and Codes Section has reviewed the PIA Plan and does not recommend approval of the PIA Plan at this time. The following comments need to be addressed in the next submittal. 1. Include the plan number "I-2012-012" in the title block of each sheet. 2. Include Development Services Department PIA activity number "T12PI00014"on cover sheet. 3. Address all redline comments including plan numbers. 4. Add note to general notes for the Design Speed and Posted Speed and Design Vehicle. 5. Provide an 8' wide graded shoulder with a ith a cross slope no greater than 2%. 6. Verify Existing and Proposed Manhole Elevations, as some do not appear to coincide with profiles (See Redlines). 7. Make sure valves or manholes are not located in curb line (vertical or header). 8. All longitudinal grades must be a minimum of +/- 0.50% See Dev. Std. 3-01.4.5. 9. All cross slopes shall be +/- 2.0% unless otherwise approved. See Dev. Std. 3-01.4.5. 10. All cross slopes shall be constant in conformance with the Typical Sections and the roadway shall not vary to match existing driveways. Driveways shall be rebuilt to match the new roadway to ensure a smooth rideable surface. 11. Provide vertical curves when the algebraic difference between the incoming and outgoing roadway grade is greater than 1 %. The minimum permitted length of a vertical curve is 100 feet. see Dev. Std. 3-01.5.B 12. Make sure all callouts in the profile are in their correct locations (See redline on sheet 4). 13. Floor slopes of all new catch basins shall be a minimum of 5.0% unless otherwise approved by TDOT Engineering. 14. Sheet 9 Proposed Elevations on Sears Bl. at Bilby Rd. appear to show a sag curve with a low point south of the existing catch basin. Please revise plans and limits of construction to ensure low points are at the catch basin. Refer to redline plans for additional comments and comment details. If you have any questions, I can be reached at 837-6647 or Richard.Leigh@tucsonaz.gov |
| 12/14/2012 | RICHARD LEIGH | PIA COORDINATOR | CUSTOMER CALLED; PLANS @ AMBASSSADOR | Completed | |
| 12/14/2012 | LANCE PETERSON | DOT STREET MAINTENANCE | REVIEW | Approv-Cond | I have reviewed this proposed plan and approve it conditionally. I have a concern with drainage. There are several sections that convey runoff to the shoulder. What is the plan to convey this runoff and prevent erosion? Lance Peterson, P.E. Streets and Traffic Maintenance 837-6777 |
| 12/14/2012 | RICHARD LEIGH | PIA COORDINATOR | OUT TO CUSTOMER | Completed |