Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Plan Number: T12PI00013
Parcel: Unknown

Review Status: Completed

Review Details: PIA - RESUBMITTAL

Plan Number - T12PI00013
Review Name: PIA - RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/04/2013 JOSE ORTIZ DOT TRAFFIC REVIEW Approv-Cond ACTIVITY NUMBER: T12PI00013
PROJECT NAME: Senior Care Facility Tanque Verde & Catalina
PROJECT ADDRESS:
PROJECT REVIEWER: Matthew Geweke, Traffic Eng Tech

Conditional Acceptance:
Traffic Engineering recommends conditional approval of the PIA Plan; therefore a revised PIA Plan is not necessarily required for re-submittal but the following items must be revised or added to the plan. Just an email response with an exchange of PDF's is acceptable in lieu of a re-submittal if needed.

1. See redlines on the submitted drawings and address the additional redline comments on Sht: 3
(creating a 3' wide mini-gore area in the reverse curve between left turn bays. Place one WS12 stripe with 6 type 'H' RPM's centered on stripe to create a tactile alert to motorists. Best field fit possible. I will be glad to be present in the field on the day of striping to assist lay-out with the striping crew and answers concerns. )

2 See Traffic Eng note attached to the plans, Sht. #3.

If you have any questions, I can be reached at 791-4259 x76665 or email Matthew.Geweke@tucsonaz.gov
01/07/2013 RICHARD LEIGH DOT ENGINEERING REVIEW Approv-Cond January 7, 2013

SUBJECT: Tanque Verde Rd and Catalina Highway - I-2012-012, T12PI00013

PROJECT REVIEWER: Richard Leigh, DOT, Permits and Codes Section

Permits and Codes Section has reviewed the PIA Plan and recomends a conditional approval of the PIA Plan. The following comments need to be addressed to submitting the mylars for final review and approval.


1. Clearly reference the the pavement sections to be used for the driveway and in Tanque Verde Rd. in the plan view.
01/07/2013 GARY WITTWER DOT LANDSCAPE REVIEW Approved
01/08/2013 LANCE PETERSON DOT STREET MAINTENANCE REVIEW Approved
02/06/2013 BLANCA ESPINO PIA COORDINATOR CUSTOMER CALLED; PLANS @ AMBASSADOR Completed
02/06/2013 BLANCA ESPINO PIA COORDINATOR OUT TO CUSTOMER Completed
12/14/2012 BESPINO1 UTILITY CLEARANCES QUEST COMMUNICATION Completed
12/14/2012 BESPINO1 UTILITY CLEARANCES TUCSON ELECTRIC POWER CO Completed
12/14/2012 BESPINO1 UTILITY CLEARANCES COX COMMUNICATION Completed
12/14/2012 BESPINO1 UTILITY CLEARANCES SOUTHWEST GAS CORP Completed
12/14/2012 BESPINO1 UTILITY CLEARANCES EL PASO NATURAL GAS Completed
12/14/2012 BESPINO1 UTILITY CLEARANCES KINDER MORGAN ENERGY Completed
12/14/2012 BESPINO1 UTILITY CLEARANCES COT STREETS DIVISION Completed
12/14/2012 BESPINO1 UTILITY CLEARANCES COT WATER NEW DEVELOPMENT Completed
12/21/2012 BESPINO1 UTILITY CLEARANCES PC WASTEWATER MGMT Completed