Review Date Reviewer's Name Type of Review Description Status Comments
01/04/2013 ELIZABETH LEIBOLD ENGINEERING REVIEW Denied DATE: January 4, 2013
FOR: Jesse Ross
SUBJECT: Amphi High School Additions / Renovations Review
REVIEWER: Elizabeth Leibold, P.E.
ACTIVITY NUMBERS: T12OT001659 (floodplain use permit), T12CM07840

SUMMARY: Engineering Division of Planning & Development Services Department has received the floodplain use permit application submittal for the above referenced property. Engineering Division of Planning & Development Services Department does not recommend approval until the following comments are addressed.

COMMENTS:
1) 7.14.4: Provide hydrology report showing that proposed structures that are being improved are not within the floodplain. Otherwise, project will be required to submit substantial improvement paperwork:
a) Provide the total cost of the improvements for this project. See attached guideline (page 8-8) for sample of items that are included or excluded. Keep in mind that all future improvements will be cumulative in percentage, to include this project. (item vii below)
b) Provide existing value (assessor value or appraisal not including the land) of each of the structure(s) for this project. (item vi below)
c) Supply the following for all work to be authorized for this permit application:
i) An 8-1/2" x 11" map locating proposed improved structures on this parcel
ii) Title of improvement
iii) Description of improvement
iv) Provide all related permit activity number(s)
v) Type of assessment used for valuation of the proposed improvements
vi) Value of the existing building structure
vii) Value of proposed improvement in U. S. Dollars
viii) A calculated percent improvement

Let me know if you would like this reviewed at the counter. For any questions, call me at 837-4934.