Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: PLANS OK TO SUBMIT - FLOODPLAIN
Permit Number - T12OT01531
Review Name: PLANS OK TO SUBMIT - FLOODPLAIN
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/07/2012 | JASON GREEN | ENGINEERING | REVIEW | Approved | November 7, 2012 FLOODPLAIN USE PERMIT NO.: T12OT01531 ADDRESS: 250 N Harrison Road Tucson, Arizona 85748 PROPERTY OWNER: COT Real Estate Division PO Box 27210 Tucson, Arizona 85726 The applicant is authorized to use a portion of the FEMA Special Flood Hazard Area Zone AE per the Flood Insurance Rate Maps 04019C2308L, specifically described as: A portion of Parcel 134-01-002D For the purpose of installing a Generator for an existing communication tower. The applicant agrees to comply with City of Tucson Floodplain and Erosion Hazard, and Watercourse Amenities, Safety and Habitat regulations, and are particularly bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Responsibility for renewal of this permit, if necessary, is with the applicant. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, Land Use Code, or any other Federal, State, County, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under City of Tucson Floodplain and Erosion Hazard Regulations and Watercourse Amenities, Safety, and Habitat regulations require the issuance of an additional Floodplain Use Permit. The following 10 conditions apply to this permit: 1) This permit becomes invalid and is subject to additional floodplain review, if any required development changes the construction of the generator, or, if there is any further disturbance within the floodplain other than that outlined in this application. This floodplain use permit may be subject to conditions or restrictions designed to reduce or mitigate the potential damage or hazard to life or property resulting from the construction of the generator within the regulatory floodplain, floodway or erosion hazard areas as determined by the project engineer and accepted by the City of Tucson. 2) Except as approved by the City Engineer prior to the start of construction, development under this permit shall not obstruct, retard or divert the existing flow of floodwaters from or to adjacent properties. 3) For purposes of this permit the following flood elevations shall be used for the enclosed detached garage: Base Flood Elevation (BFE) = 2721.1 feet NAVD 1988 Regulatory Flood Elevation (RFE) = 2722.1 feet NAVD 1988 Machinery is to be elevated at or above the Regulatory Flood Elevation (RFE). 4) Floodplain Approval of elevation certificate, prepared by an Arizona State Registered Land Surveyor, is required prior to the finished construction or Final Inspection (P2F). The Elevation Certificate must include the identity and elevation of the lowest service equipment/machinery. 5) All work shall conform to the approved site plan sheets, which are made part of this permit. 6) Within 5 (five) days of issuance of this permit, and through completion of the project, notification must be posted and maintained in a conspicuous place on the job site stating "CONSTRUCTION PROCEEDING UNDER REQUIREMENTS OF CITY OF TUCSON FLOODPLAIN USE PERMIT # T12OT01531 FOR INFORMATION PLEASE CALL 791-5550." 7) This Floodplain Use Permit and plans shall be kept in a readily accessible location on site at all times. 8) Any additional future disturbance of the floodplain shall have separate floodplain use permit applications submitted to this office for review and approval. 9) See the associated activity T11CM02570 10) This permit is specific to the improvements for 250 N Harrison Rd as indicated on the approved plans. It shall not apply to any other structure or property, whether attached or unattached, not specified under this permit. Renewal of this permit will require a new application, review and approval of that application by the City of Tucson, Development Services Department, Engineering Division. This permit may be renewed for up to one year, in the absence of Registered Plant authorization, at the sole discretion of the City Engineer or designated representatives. This Floodplain Use Permit will be automatically revoked and becomes invalid if conditions are not complied with, as set forth in this permit. APPLICANT NAME: Patriot Towers, Inc ADDRESS: 9332 N 95th Way B203 Scottsdale, AZ 85285 PHONE: 480-421-0234 CONTRACTOR: Patriot Towers, Inc ADDRESS: 9332 N 95th Way B203 Scottsdale, AZ 85285 PHONE: 480-421-0234 (EXPIRATION DATE) Month: _11 Day: 07 Year: 2013 SIGNATURE OF APPLICANT DATE The applicant is authorized by the City Engineer to receive a floodplain use permit subject to the above referenced conditions and restrictions. |