Permit Number: T12OT01469
Parcel: 125073460

Address:
422 N PLUMER AV

Review Status: Active

Review Details: FLOODPLAIN

Permit Number - T12OT01469
Review Name: FLOODPLAIN
Review Status: Active
Review Date Reviewer's Name Type of Review Description Status Comments
11/16/2012 LOREN MAKUS ENGINEERING REVIEW Approved November 20, 2012

The applicant is authorized to use a portion of the flood hazard area (FIRM Panel 2277L, FEMA Zone AE) in the City of Tucson at 422 North Plumer Avenue for the purpose of constructing residential/commercial building.

The applicant agrees to comply with City of Tucson Floodplain and Erosion Hazard regulations, and is particularly bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Responsibility for renewal of this permit, if necessary, is with the applicant. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, Land Use Code, or any other Federal, State, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under City of Tucson Floodplain and Erosion Hazard Regulations and Watercourse Amenities, Safety, and Habitat regulations require the issuance of an additional Floodplain Use Permit.

The following conditions shall apply to this permit.

1. All work shall conform to the attached plans (Drainage Report of November 16, 2012 by Christopher B. Rod and associated building plans) which are made part of this permit.

2. No fill shall be placed on the project site outside of the building footprint and the driveway area. The area of allowed fill shall not extend into the proposed parking space.

3. The proposed building is within the regulatory floodplain. The floodplain 100-year water surface elevation (WSE) just upstream of the proposed building is 2442.13 feet. The building's finished floor elevation, including the floor of the enclosed garage, must be elevated 1 foot above the floodplain 100-year WSE. The building's lowest finish floor, utilities, machinery, equipment (i.e. furnaces, water heaters, heat pumps, air conditioners and their associated equipment, including all electrical equipment), and any open utility platform that provides utility services for the proposed structure must be placed at a minimum of 2443.13 feet above see level, NAVD88 as certified by a Registered Land Surveyor. This Certification (Elevation Certificate) is required and must be completed and returned to Development Services Department, Engineering Division, on the first floor of the County/City Public Works Building at 201 N. Stone Avenue. This Certification must be completed and returned prior to the final inspection, occupancy of the structure, or issuance of Certificate of Occupancy.

4. An elevation certificate is also required before the stem walls and floors are constructed.

5. A certification from a surveyor shall also be required to establish the house is constructed outside of the erosion hazard setback as determined by the approved engineering report.

6. The existing drainage patterns at the property lines shall not be obstructed.

7. Except as approved by the City Engineer prior to the start of construction, development under this permit shall not obstruct, retard or divert the existing flow of floodwaters from or to adjacent properties.

8. This permit becomes invalid and is subject to additional floodplain review, if any required development permit (s') changes the configuration of the structure and or site development.

9. Return of the completed elevation certificate must be submitted to the Records Department, 201 N. Stone Ave. prior the issuance of a Certificate of Occupancy.

10. Any walls or fences to be constructed will require a separate encroachment analysis and a separate Floodplain Use Permit.

This Floodplain Use Permit will be automatically revoked and becomes invalid if conditions set forth in this permit are not complied with.

Final Status

Task End Date Reviewer's Name Type of Review Description
10/22/2012 ANY APPROVAL SHELF RECEIVED