Permit Number: T12OT01425
Parcel: 13631019U

Review Status: Completed

Review Details: FLOODPLAIN

Permit Number - T12OT01425
Review Name: FLOODPLAIN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
10/25/2012 ELIZABETH LEIBOLD ENGINEERING REVIEW Approved DATE: October 25, 2012
TO: Clint Glass, P.E., CMG Drainage Engineering, Inc
SUBJECT: Floodplain Use Permit Engineering 1st submittal Review
LOCATION: 10,100 E Millmar Rd
ACTIVITY NUMBER: T12OT01425

SUMMARY: Engineering has reviewed the CMG hydrology report dated 29, 2012 for 10100 E Millmar Rd, and recommends approval. For permits, provide a grading plan that shows conformance to approved report, to include the following per DS Sec.10-02 and Tucson Code Chap 26 Article I Sec.26-8(d)(2):
1) Show alternate / emergency all weather access route on grading plan. Provide topography and or spot elevations showing maximum depth of 100-year flow.
2) Provide spot elevations for both existing and proposed conditions around structure.
3) Show and label erosion protection and lowest adjacent grades of proposed pad on grading plan per Sec.26-8(d)(2).
4) Label minimum FFE based on approved hydrology report.
5) Label floodplain, 100-yr BFE, and erosion hazard setbacks on plan.

Please be aware that an elevation certificate will be required for the addition and may be applied for at grading permit application or at minimum prior to commencement of construction. Building plans may be submitted for concurrent review. Call or email me for clarifications at 837-4934 / elizabeth.leibold@tucsonaz.gov

Elizabeth Leibold, P.E., CFM, CPM
Civil Engineer
Engineering Division
Planning & Development Services
10/25/2012 ELIZABETH LEIBOLD ENGINEERING REVIEW Approved BFE PER CMG REPORT: 2759.3
10/25/2012 ELIZABETH LEIBOLD ENGINEERING REVIEW Approved Revision to the site plan and floodplain use permit for a new propsoed driveway access that meets FIRE standards for a double shot chip seal and hammer head turn around to allow fire access to remove the fire sprinkler system. JG

Final Status

Task End Date Reviewer's Name Type of Review Description
01/31/2013 CPIERCE1 OUT TO CUSTOMER Completed