Permit Number: T12OT01052
Parcel: 112051640

Review Status: Completed

Review Details: FLOODPLAIN

Permit Number - T12OT01052
Review Name: FLOODPLAIN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/16/2012 LOREN MAKUS ENGINEERING REVIEW Approved July 16, 2012

The applicant is authorized to use a portion of the flood hazard area (FEMA zone AE, Panel 1689L) in the City of Tucson at 2240 East Monte Vista Drive for the purpose of constructing a garage addition to an existing residential building.

The applicant agrees to comply with City of Tucson Floodplain and Erosion Hazard regulations and is particularly bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Responsibility for renewal of this permit, if necessary, is with the applicant. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, Land Use Code, or any other Federal, State, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under City of Tucson Floodplain and Erosion Hazard Regulations and Watercourse Amenities, Safety, and Habitat regulations require the issuance of an additional Floodplain Use Permit.

The following conditions shall apply to this permit.

1. All work shall conform to the attached plans for a new attached garage (T12CM04272) which are made part of this permit.

2. The proposed building is within a regulatory floodplain. The proposed garage shall be provided with flood vents in the lowest 1 foot of at least 2 separate walls. The total area of the vents shall be at least 425 square inches.

3. The existing drainage patterns at the property lines shall not be obstructed.

4. Except as approved by the City Engineer prior to the start of construction, development under this permit shall not obstruct, retard or divert the existing flow of floodwaters from or to adjacent properties.

5. This permit becomes invalid and is subject to additional floodplain review, if any required development permit (s') changes the configuration of the structure and or site development.

6. Any patio walls to be constructed will require a separate Floodplain Use Permit.

This Floodplain Use Permit will be automatically revoked and becomes invalid if conditions set forth in this permit are not complied with.
The applicant is authorized by the City Engineer to receive a floodplain use permit subject to the above referenced conditions and restrictions.

Final Status

Task End Date Reviewer's Name Type of Review Description
07/16/2012 CPIERCE1 OUT TO CUSTOMER Completed