Permit Review Detail
Review Status: Completed
Review Details: FLOODPLAIN
Permit Number - T12OT00815
Review Name: FLOODPLAIN
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/27/2012 | ELIZABETH LEIBOLD | ENGINEERING | REVIEW | Denied | Grading permit with sealed copy of drainage report will be required for residential development. The applicant is authorized to use a portion of FEMA and City of Tucson jurisdictional floodplain, specifically described as: 1006 N ANITA AV, Tucson AZ 85705, within Township 14S, Range 13E, Section 11, Parcel 116-16-0120, being MCKINLEY PARK AMENDED LOT 11 BLK 1, Lat 32.234495, Long -110.981301, for the purpose of improvements for SFR construction within West University Wash floodplain. The applicant agrees to comply with City of Tucson Floodplain and Erosion Hazard, and if applicable, Watercourse Amenities, Safety and Habitat regulations, and are particularly bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Responsibility for renewal of this permit, if necessary, is with the applicant. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, Land Use Code, or any other Federal, State, County, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under the City of Tucson Floodplain and Erosion Hazard Regulations require the issuance of an additional Floodplain Use Permit. The following 12 conditions apply to permit T12OT00815: 1) For a PDSD Engineering Inspection, call IVR (740-6970), or contact PDSD Engineering at 837-4991, or schedule inspections online at: http://www.ci.tucson.az.us/dsd/Online_Services/Online_Permits/online_permits.html 2) Grading Plan with a sealed copy of the drainage report is required for this project. 3) Floodplain Use Permit & plans shall be kept in readily accessible location on site at all times. 4) No disturbance is permitted other than area within the lot and as shown on the approved plans. 5) From floodplain data derived from Hydrology Report for Single Family Residence at 1006 N. Anita Avenue prepared by Chris Rod, P.E. of JE Fuller, BFE = 2343.4 NAVD88. Minimum FFE elevation = 2344.4. 6) Submit Elevation Certifications by a Land Surveyor registered in the State of Arizona for pad elevation (prior to pouring slab), and later for finished construction. PDSD Engineering has the preliminary elevation certificate filled out for the RLS to use, as needed. First elevation certificate must be submitted prior to pouring concrete slab to assure minimum height is achieved. Concrete slab may not be poured until PDSD Engineering accepts Building-Under-Construction elevation certificate. An additional El Cert is needed for Finished-Construction. Assure the lowest elevation of any attached garage and the utility equipment to service the building is provided in C2e) and E4 on Finished Construction el cert. Notations should be added to clarify type of equipment and location. Submit color photos for Item A6 of the Finished Construction Elevation Certificate. Approved Final El Cert is required prior to final approval of permits for this development; assure the El Certs are provided to the City of Tucson PDSD Engineering Division. 7) PDSD Engineering Inspections are required prior to final floodplain inspection. 8) Within 5 (five) days of issuance of this permit, and through completion of the project, notification must be posted and maintained in a conspicuous place on the job site stating "CONSTRUCTION PROCEEDING UNDER REQUIREMENTS OF CITY OF TUCSON FLOODPLAIN USE PERMIT # T12OT00815. FOR INFORMATION PLEASE CALL 791-5550." 9) Except as approved by the City Engineer prior to the start of construction, development under this permit shall not obstruct, retard or divert the existing flow of floodwaters from or to adjacent properties. 10) This permit becomes invalid and is subject to additional floodplain review, if any required development permit changes the configuration of the improvement, or, if there is any further disturbance within the floodplain other than that outlined in this application. This floodplain use permit may be subject to conditions or restrictions designed to reduce or mitigate the potential damage or hazard to life or property resulting from development within the regulatory floodplain, floodway or erosion hazard areas as determined by the project engineer and accepted by the City of Tucson and PCRFCD. 11) If any walls are to be built, at-grade wall openings will be needed & will need to be inspected by City of Tucson PDSD Engineering. 12) See also any associated grading or building permits. ***Do not issue FPUP without sealed copy of drainage report and grading plan submitted/reviewed/approved. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 07/31/2012 | FERNE RODRIGUEZ | OUT TO CUSTOMER | Completed |