Review Details: PLANS OK TO SUBMIT - FLOODPLAIN

Permit Number - T12OT00741
Review Name: PLANS OK TO SUBMIT - FLOODPLAIN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/11/2012 LOREN MAKUS ENGINEERING REVIEW Approved May 11, 2012

The applicant is authorized to use a portion of the flood hazard area in the City of Tucson on the property described as 3911 North Tucson Boulevard for the purpose of constructing a new building at a residential property.

The applicant agrees to comply with City of Tucson Floodplain and Erosion Hazard regulations, and is particularly bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Responsibility for renewal of this permit, if necessary, is with the applicant. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, Land Use Code, or any other Federal, State, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under City of Tucson Floodplain and Erosion Hazard Regulations and Watercourse Amenities, Safety, and Habitat regulations require the issuance of an additional Floodplain Use Permit.

The following conditions shall apply to this permit:

1. All work shall conform to the attached plans (Drainage Report and all activity number T11CM03883) which are made part of this permit.

2. Any building shall be placed on a engineered pad, compacted to 95% density, extending twenty-five (25) feet beyond the buildings foundation, unless a study prepared by a state-registered professional civil engineer and approved by the city engineer shows that a lesser distance is acceptable.

3. The proposed building(s) is/are impacted by the regulatory floodplain. The floodplain 100-year water surface elevation (WSE) just upstream of the (existing or proposed) building(s) is 2354.5 feet. The building(s) finished floor elevation must be elevated 1 foot above the floodplain 100-year WSE. This can be achieved by either building up the building pad to the 100-year WSE or higher, or elevating the building by any other acceptable method such as stem walls, piers, etc, depending on what the drainage report, the engineer or the owner is proposing. The building lowest finish floor, utilities, machinery, equipment (i.e. furnaces, water heaters, heat pumps, air conditioners and their associated equipment, including all electrical equipment), or an open utility platform that provides utility services for the structure on this property, under this permit shall, be placed at a minimum of 2355.5 (1 foot above 2355.5) feet above see level, NAVD88 as certified by a Registered Land Surveyor. This Certification (Elevation Certificate) is required and must be completed and returned to Development Services Department, Engineering Division, on the first floor of the County/City Public Works Building at 201 N. Stone Avenue. This Certification must be completed and returned prior to the final inspection, occupancy of the structure, or issuance of Certificate of Occupancy.

4. The existing drainage patterns at the property lines shall not be obstructed.

5. Except as approved by the City Engineer prior to the start of construction, development under this permit shall not obstruct, retard or divert the existing flow of floodwaters from or to adjacent properties.

6. This permit becomes invalid and is subject to additional floodplain review, if any required development permit (s') changes the configuration of the structure and or site development.

7. Adhere to specifications outlined in Section C, C2 of the elevation certificate.

8 Return of the completed elevation certificate must be submitted to the Planning and Development Service Department, Engineering Section, 201 N. Stone Ave. prior the issuance of a Certificate of Occupancy.

10. Any patio walls to be constructed will require a separate Floodplain Use Permit.

This Floodplain Use Permit will be automatically revoked and becomes invalid if conditions set forth in this permit are not complied with.